correct answers
Min #receptacles in a garage - ** VERIFIED ANSWERS **✔✔1
Mobile home service equipment shall be line of sight and no more than ____ from the exterior wall of
the home - ** VERIFIED ANSWERS **✔✔30'
If a service conductor is over 300V but less than 600V, what is the minimum clearance of that service
conductor if it runs in residential and commercial areas that are not subject to traffic? - ** VERIFIED
ANSWERS **✔✔15'
A power meter must be a minimum of ____ feet away from any door, gas meter, or window opening. -
** VERIFIED ANSWERS **✔✔3
A rod-type grounding electrode should have a minimum diameter of - ** VERIFIED ANSWERS **✔✔5/8"
Conductors entering buildings shall be protected: - ** VERIFIED ANSWERS **✔✔To the point of
entrance
A grounding electrode must be in contact with soil a minimum: - ** VERIFIED ANSWERS **✔✔8'
If a raceway has various conductors coming from different systems, then you should group each system
separately every: - ** VERIFIED ANSWERS **✔✔6'
What is the maximum distance a service conductor can run over a roof? - ** VERIFIED ANSWERS
**✔✔6'
Soldered connections are not permitted for - ** VERIFIED ANSWERS **✔✔Grounded connections