exterior walls are noncombustible
Type III
interior building elements are fire-
retardant-wood-framing
exterior walls are noncombustible
Type IV
interior building elements are
laminated wood
exterior walls, interior building
Type V elements, structural elements can
be anything
1 hour fire rating required
partitions between tenant spaces
(1/3)
1 hour fire rating required
partitions along a public corridor
(2/3)
1 hour fire rating required partitions that demise assembly
(3/3) occupancies of 750 sq.ft. or greater
between assembly and mercantile
2 hour fire rating required
occupancy
,2 hour wall requires what
1.5 hour door
door?
1.5 hour wall requires what
1 hour door
door?
45 minute door
1 hourwall requires what
door?
*can be 20 minutes between public
corridor and suite
45 minute door
45 minute wall requires what
door?
*can be 20 minutes between public
corridor and suite
all doors with fire protection glazing in fire rated partitions,
rating must have self-closing doors and sidelights can not exceed
devices 240 sq.ft.
storage rooms exceeding 100 there must be audio/visual signal
sq.ft. must have 1 hour fire device in every restroom, hallway,
rated walls lobby and general assembly area
audio/visual mounting height 6'-8" - 7'-6" a.f.f.
1 fire extinguisher, per how
3,000 sq.ft.
many square feet?
fire extinguishers must be
located no further than ___ 75'
from the furthest occupant?
,means of egress ceiling
no less than 7'-6"
height?
protruding objects cannot
reduce the width of an 44"
accessible route below?
protruding objects cannot
reduce the height of an 6'-8"
accessible route below?
protruding objects between
___ - ___ a.f.f. must not 27" - 80", 4"
protrude more than ___
turning radius? 60"
passing space requirements? 60" x 60" every 200'
common path of egress must
100'-0"
no exceed?
travel distance must no
250'-0"
exceed?
door opening minimum? 36"
push/pull clearances 12" (48"), 18" (60")
which side of a door should a
power door operator be the latch side
located?
power door operator face
6"D or 2" x 4" square
dimension?
, door hardware to be located
34" - 48" a.f.f.
at?
how many push plates are
required for a power operated 2
door?
1 - 7" - 8" a.f.f.
push plates to be located at
what height?
2 - 30" - 44" a.f.f.
actuation bar located at what
5" a.f.f bottom - 35" a.f.f. top
height?
maximum threshold height? 1/2"
how far can a door project into
7"
a path of egress?
doors must swing in the
direction of egress unless from
50
a room or area with an
occupant load less than?
distance between two doors in
48"
open sequence?
exit doors must be placed at a one-half
distance that is equal to or
greater than: