A fill line in an oil burner system is a line used to: Fill the storage tank with oil. The aquastat is located Below the water line. All heating, combustion, and cooking equipment shall be installed with adequate clearances from _______ construction. Combustible The equipment must be provided with ______ or the building construction shall be _____ _____. Insulation. Fire Protected During operation the surface of combustible construction materials will not be raised to a temp higher than _____ degrees F. 170 degrees Equipment shall be so that the means of access for ordinary operation and maintenance will not be _______. Hazardous Acceptance Tests: Boilers shall not be placed in operation until they have been _____ and ____ and an equipment ____ _____ has been issued by the ______. Inspected and tested. Use permit, commissioner Periodic Inspections: All boilers must be inspected at least _____ a _____ including chimney connections. Once a year Owners Annual Statement: The owner of each boiler shall file an _____ written statement with the ________, specifying the _____of each boiler and ____

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

P99 LOW PRESSURE BOILER
EXAM QUESTIONS AND COMPLETE
SOLUTIONS

A fill line in an oil burner system is a line used to:
Fill the storage tank with oil.
The aquastat is located
Below the water line.
All heating, combustion, and cooking equipment shall
be installed with adequate clearances from _______
construction.
Combustible
The equipment must be provided with ______ or the
building construction shall be _____ _____.
Insulation.
Fire Protected
During operation the surface of combustible
construction materials will not be raised to a temp
higher than _____ degrees F.
170 degrees
Equipment shall be so that the means of access for
ordinary operation and maintenance will not be
_______.
Hazardous
Acceptance Tests:
Boilers shall not be placed in operation until they have
been _____ and ____ and an equipment ____ _____
has been issued by the ______.

, Inspected and tested.
Use permit, commissioner
Periodic Inspections: All boilers must be inspected at
least _____ a _____ including chimney connections.
Once a year
Owners Annual Statement: The owner of each boiler
shall file an _____ written statement with the
________, specifying the _____of each boiler and
______ for inspection.
Annual, commissioner, location, arrangement.
Field Tests: all piping and oil storage tanks shall be
_______ tested for tightness by the ______ before the
system is operated.
Hydrostatically, contractor
The piping shall be tested at _____ times the max
working pressure applicable to that part of the piping
system but at a pressure ____ than the test pressure
required for the storage tank.
1/2, less
The min pressure for testing tanks shall be ____ times
the max working pressure but in no case less than
____ psi.
1 1/2, 25 psi
The hydrostatic pressure must be maintained until all
____ and _____ have been visually inspected for ___,
but in no case less than _____ hour.
Joints, connections, leaks, 1/2 hour.
A record must be kept of the pressure test showing
the name of the _____ and the _____ at which the
piping and tank were tested.
Contractor, pressure

Geschreven voor

Vak

Documentinformatie

Geüpload op
9 januari 2025
Aantal pagina's
13
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
AcademicSuperStore

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
AcademicSuperStore Chamberlin College of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2
Lid sinds
1 jaar
Aantal volgers
0
Documenten
798
Laatst verkocht
1 jaar geleden
AcademicSuperStore

I have solutions for following subjects: Nursing, Business, Accounting, statistics, chemistry, Biology and all other subjects. Nursing Being my main profession line, I have essential guides that are Almost A+ graded, I am a very friendly person: If you would not agreed with my solutions I am ready for refund

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen