HERS Rater Exam Questions and
Answers 100% Pass
What do HERS Providers provide? - ✔✔They provide software, oversight, marketing assistance, and
quality assurance for the Rater.
What role does a HERS Trainer play? - ✔✔The Trainer trains Raters on how to perform HERS ratings.
What are some of the responsibilities of a HERS Rater? - ✔✔The Rater's responsibilities include
inspecting and testing the minimum rated features of the home, entering the data into a RESNET
accredited software tool, and providing the client with reports generated by the software.
Why was RESNET created and by whom? - ✔✔RESNET was created to use a scoring system that could
compare the energy use of different houses with each other on a level playing field. It was created to
oversee the HERS industry, provide standards for accreditation of Raters, Providers and Trainers, ethics
and protocols for inspection, testing and software analysis. It was created by the National Association of
State Energy Officers (NASEO) and Energy Rated Homes of America.
What are the minimum rated features of a home? - ✔✔The minimum rated features of a home include but
are not limited to the foundation, walls, roof-ceiling, rim joist, doors, windows, skylights, air infiltration,
heating and cooling equipment, heating and cooling distribution system, duct leakage, domestic water
heating, passive solar design, and solar water heating.
Can any energy analysis software be used to produce a HERS rating? - ✔✔No -- The software must be a
RESNET accredited software tool.
Emily Charlene © 2025, All Rights Reserved.
, 2|Page
Is a Home Energy Rater required to verify compliance with the local energy code? - ✔✔No - The rater is
not required to determine compliance with regulatory requirements such as construction codes.
If a Rater enters an existing home to perform inspections and testing and the owner's 9 foot Burmese
python is loose, does the Rater have to complete the inspection and testing? - ✔✔No - The Rater is not
required to enter any area or perform any procedure that is likely to be dangerous to the Rater.
Is a Rater required to perform Manual J load calculations? - ✔✔No - The Rater is not required to offer or
perform HVAC system design or sizing consultation.
What is a British thermal unit? - ✔✔A British thermal unit (Btu) is the amount of heat required to raise
the temperature of one pound of water on degree Fahrenheit at sea level when the water is 39.2°F.
A homeowner has paid for 17 CCF of natural gas on their monthly bill. How many Btu's did they use? -
✔✔1 CCF = 102,000 Btu's
17 CCF = 17 x 102,000 = 1,734,000
How many therms? - ✔✔1 CCF of natural gas = 1 therm
17 CCF of natural gas = 17 therms
How many kWh are in 14,000 Btu's? - ✔✔1 kWh = 3,413 Btu's
14,000 Btu's / 3,413 Btu's = 4.1 kWh
How many therms are in 18 CCF of natural gas? - ✔✔1 CCF of natural gas = 1 therm
18 CCF of natural gas = 18 therms
What is the building envelope? - ✔✔The building envelope is an air barrier and thermal boundary that
are continuous and touching and separate conditioned space from unconditioned space or the outside.
Emily Charlene © 2025, All Rights Reserved.