Sensory Tens Parameters
Indication, Pulse duration, Pulse rate, Intensity, Electrode placement, Mode, RX
time, Onset of relief, Duration of relief, Fiber activation
Indication- Acute pain
Pulse duration- 60-100 usec
Pulse rate- 80-150 pps
Intensity- Sensory
Electrode placement- Bipolar: Painful area, NR or dermatome
Mode- Modulated
RX time- 15-30 min, 1-2x/day
Onset of relief- <10 minutes
Duration of relief- minutes
Fiber activation- A-beta (gate control)
Brief-Intense Tens Parameters
Indication, Pulse duration, Pulse rate, Intensity, Electrode placement, Mode, RX
time, Onset of relief, Duration of relief, Fiber activation
Indication- Pain prior to rehab
Pulse duration- 1 msec
Pulse rate- Variable (>= 100pps)
, Intensity- Noxious (to tolerance)
Electrode placement- Bipolar: Motor pt, trigger pt, acupuncture pt
Mode- Burst
RX time- 10-20 min, 1-2x/day
Onset of relief- <15 min
Duration of relief- 30 min
Fiber activation- C-fibers (enkephalin)
Motor Tens Parameters
Indication, Pulse duration, Pulse rate, Intensity, Electrode placement, Mode, RX
time, Onset of relief, Duration of relief, Fiber activation
Indication- Chronic pain
Pulse duration- 150-250 usec
Pulse rate- 1-10 pps
Intensity- Motor
Electrode placement- Bipolar: Motor pt, trigger pt, acupuncture pt
Mode- Burst
RX time- 15-30 min, 1-2x/day
Onset of relief- 20-40 min
Duration of relief- 6-7 hours
Fiber activation- A-delta (endorphin) A-alpha (motor)
Acute Pain IFC Parameters
Pulse rate, Intensity, Electrode placement, Vector, Rx time