CERTIFICATION TRAINING EXAM (ACTUAL
2025) QUESTIONS WITH CORRECT ANSWERS
True or false: In a solar array with Enphase microinverters, all
of the solar panels should have the same orientation for
maximum energy production.
False
The energy production of each micro/panel is independent
from the others
Do solar panels deliver a constant STC rated output when
installed at most homes or businesses?
A. No, but it is required that solar panels never exceed the
inverter rating
B. No, solar panels have a maximum output rating and do not
exceed that
C. No, solar panels typically are warmer and have less light
reaching them than in the STC factory test conditions
D. Yes, if they didn't the customers would return them or get
payment as part of their 20 year warranties
,ENPHASE SOLAR PV INSTALLATION
CERTIFICATION TRAINING EXAM (ACTUAL
2025) QUESTIONS WITH CORRECT ANSWERS
C. No, solar panels typically are warmer and have less light
reaching them than in the STC factory test conditions
When designing solar systems, selecting the right
microinverter and solar panel pairing based on power output
requires analysis. Which of the following statements is the
most accurate?
A. Because microinverters are a series DC string circuit, the
correct minimum and maximum number must be carefully
observed
B. To claim STCs the output of each microinverter can be no
less than 75% of the output of the solar panel that it is
connected to
C. Selecting solar modules with power output lower than the
inverter output is a good idea because all solar panel output
will always get captured
D. You cannot have the solar panel DC wattage exceed the
microinverter output wattage as the microinverter could get
damaged
UNSURE, but it's either
,ENPHASE SOLAR PV INSTALLATION
CERTIFICATION TRAINING EXAM (ACTUAL
2025) QUESTIONS WITH CORRECT ANSWERS
B. To claim STCs the output of each microinverter can be no
less than 75% of the output of the solar panel that it is
connected to
OR
C. Selecting solar modules with power output lower than the
inverter output is a good idea because all solar panel output
will always get captured
(I tried A and D and both were wrong, but I have no more
attempts - so let me know which one it is so I can update this)
The Enlighten Mobile app is available for which smartphone
and tablet devices?
A. Fire Mobile and Palm OS
B. Windows Mobile and Blackberry
C. iOS and Android
, ENPHASE SOLAR PV INSTALLATION
CERTIFICATION TRAINING EXAM (ACTUAL
2025) QUESTIONS WITH CORRECT ANSWERS
D. Alexa and Siri
C. iOS and Android
True or false: Refer to the image, the Enlighten Manager
Services Tab shown up top, is for warranty repairs only.
False
True or false: When using the Enlighten Manager "Graphs"
tab to troubleshoot CT installation and metering errors, it can
be helpful to change which source data comes from.
To select the data source, go to the settings tab then select
either microinverter measurements or meter (CT)
measurements.
True
True or false: A list of microinverters can be found under the
"Devices" tab.
True