P-99 Low Pressure Boiler COF FDNY Exam
Questions And Answers 100% Guaranteed
Pass.
A fill line in an oil burner system is a line used to: - Answer✔Fill the storage tank with oil.
The aquastat is located - Answer✔Below the water line.
All heating, combustion, and cooking equipment shall be installed with adequate clearances
from _______ construction. - Answer✔Combustible
The equipment must be provided with ______ or the building construction shall be _____
_____. - Answer✔Insulation.
Fire Protected
During operation the surface of combustible construction materials will not be raised to a temp
higher than _____ degrees F. - Answer✔170 degrees
Equipment shall be so that the means of access for ordinary operation and maintenance will
not be _______. - Answer✔Hazardous
Acceptance Tests:
Boilers shall not be placed in operation until they have been _____ and ____ and an equipment
____ _____ has been issued by the ______. - Answer✔Inspected and tested.
Use permit, commissioner
Periodic Inspections: All boilers must be inspected at least _____ a _____ including chimney
connections. - Answer✔Once a year
Owners Annual Statement: The owner of each boiler shall file an _____ written statement with
the ________, specifying the _____of each boiler and ______ for inspection. - Answer✔Annual,
commissioner, location, arrangement.
1|Page
, ©SIRJOEL 2024/2025 ALL RIGHTS RESERVED.
Field Tests: all piping and oil storage tanks shall be _______ tested for tightness by the ______
before the system is operated. - Answer✔Hydrostatically, contractor
The piping shall be tested at _____ times the max working pressure applicable to that part of
the piping system but at a pressure ____ than the test pressure required for the storage tank. -
Answer✔1/2, less
The min pressure for testing tanks shall be ____ times the max working pressure but in no case
less than ____ psi. - Answer✔1 1/2, 25 psi
The hydrostatic pressure must be maintained until all ____ and _____ have been visually
inspected for ___, but in no case less than _____ hour. - Answer✔Joints, connections, leaks, 1/2
hour.
A record must be kept of the pressure test showing the name of the _____ and the _____ at
which the piping and tank were tested. - Answer✔Contractor, pressure
Gas piping must be tested by the _____ before operation. - Answer✔Contractor
For oil burning systems, ____ ____ giving instructions for the care and operation of the system
shall be permanently located in an easily _____ and _____ location near the equipment. -
Answer✔Instruction Cards, visible, accessible
No oil burning equipment shall be operated until an equipment ____ _____ has been issued by
the commissioner, the requirements of the ____ ____ control code have been met and until the
approval for the storage of ____ ____ has been given by the fire commissioner. - Answer✔Use
permit, air pollution, fuel oil
Every oil burning installation that is not fully automatic or requires preheating shall be operated
under the direct supervision of a person holding a ____ ___ ______ issued by the FD. -
Answer✔COF
Such person must be in the building at ____ ____ while in operation and present in the _____
_____ during startup. - Answer✔All times, boiler room
After any repairs to the boiler are made, ______ shall check the repairs and the functioning of
all ____ _____ and the positioning of the ______. - Answer✔Operators, control devices, valves
All heating and combustion equipment that is fired with solid, liquid, or gas fuels, must comply
with the requirements of the ____ _____ _____ code. - Answer✔Air pollution control
Low Temp Equipment have a temp of ____ degrees at the point of leaving the equipment. -
Answer✔600 or less
Median Temp Equipment have a temp of between ___ and ___ degrees F at the point of leaving
the equipment under normal conditions. - Answer✔600 and 1000
2|Page