1. True (IPC 425.4) <Ans> A 4-inch by 3-inch closet bend shall be acceptable. T/F
2. 10 (IPC 403.1) <Ans> What is the minimum number of toilets in an
educational facility men's room if the facility enrolls 500 people?
3. accessable <Ans> "Drinking fountains shall be located on a/an route."
4. 2" (IPC 406.2) <Ans> What is the minimum waste connection for an automatic
clothes washer?
5. 30", 56" (IPC 405.3.1) <Ans> Water closet compartments shall be not less
than inches in width and
inches in depth for wall-hung water closets.
6. approved (IPC 402.1) <Ans> Plumbing fixtures shall be constructed of
materials.
7. 12", 60" (IPC 405.3.5) <Ans> The walls or partitions shall begin at a height not
greater than inches from and extend not less than inches above the
finished floor surface.
8. False, 120 degrees (IPC 412.5) <Ans> The hot water supplied to bathtubs and
whirlpool bathtubs shall be limited to not greater than 110°F. T/F
9. 30", 60" (IPC 405.3.1) <Ans> Water closet compartments shall be not less
1/
16
,than inches in width and not less than
inches in depth for floor-mounted water closets.
10. 1/4" (IPC 421.3) <Ans> Removable shower strainers openings shall not be les
than
inches in least dimension.
11. 1 1/4" (IPC 419.3) <Ans> What is the minimum waste connection for a lavator
12. 2' (IPC 413.3) <Ans> What is the minimum waste connection for a floor drain?
13. True (IPC 405.4) <Ans> The (toilet) flange shall be attached to the drain and
anchored to the structure. T/F
14. 30 (IPC 405.3.5) <Ans> The horizontal dimension between walls or partitions
at each urinal shall be not less than inches.
15. prohibited <Ans> Any water closet that permits siphonage of the contents of
the bowl back into the tank shall be . Trough urinals shall be . T/F
16. two (IPC 403.1.3) <Ans> Where or more toilet rooms are provided for
each sex, the required number oflavatories shall be distributed proportionately to
the required number of water closets.
17. False. 120 degrees (IPC 412.10) <Ans> Head shampoo sink faucets shall be
supplied with hot water that is limited to not more than 110°F (49°C) by a water-
tempera- ture-limiting device. T/F
2/
16
, 18. 1 1/2" (IPC 407.2) <Ans> What is the minimum waste connection for a bathtub
19. 3" (IPC 413.4) <Ans> In public coin-operated laundries . . . drains shall have
an outlet of not less than inches in diameter.
20. True (IPC 403.1.1) <Ans> To determine the occupant load of each sex,
the total occupant load shall be divided in half. T/F
3/
16