Horizontal insulation used in a frost protected shallow foundation system shall be protected against damage if it is located less than _______________ inches below the ground surface. A. 12 B. 15 C. 18 D. 24 - A Where waterproofing of a masonry foundation wall is necessary due to the presence of a high water table, a minimum membrane thickness of _______________ is required if the waterproofing material is polymer-modified asphalt. A. 6-mil B. 30-mil C. 40-mil D. 60-mil - C Ventilating openings providing under-floor ventilation shall be located so that at least one such opening is installed a maximum of _______________feet from each corner of the building. A. 2 B. 3 C. 5 D. 6 - B A minimum of _______________ anchor bolt(s) located _______________ of the plate section is required to anchor maximum 24-inch-long walls connecting offset braced wall panels. A. 1, within the middle third B. 1, within the middle one-half C. 2, in the outer one-fourths D. 2, within 6 inches of each end - A Unless specifically approved, what is the maximum slump permitted for concrete placed in removable foundation wall forms? A. 4 inches B. 4 1 /2 inches C. 5 inches D. 6 inches - D Where one coat of complying surface-bonding cement is used as the required dampproofing over the parging of a masonry foundation wall, the cement coating must be a minimum of _______________ inch thick. A. 1 /8 B. 3 /16 C. 1 /4 D. 3 /8 - A

Show more Read less
Institution
IRC
Course
IRC

Content preview

IRC Revision Questions Correctly Answered
Horizontal insulation used in a frost protected shallow foundation system shall be
protected against damage if it is located less than _______________ inches below
the ground surface.
A. 12
B. 15
C. 18
D. 24 - ✅✅ A

Where waterproofing of a masonry foundation wall is necessary due to the
presence of a high water table, a minimum membrane thickness of
_______________ is required if the waterproofing material is polymer-modified
asphalt.
A. 6-mil
B. 30-mil
C. 40-mil
D. 60-mil - ✅✅ C

Ventilating openings providing under-floor ventilation shall be located so that at
least one such opening is installed a maximum of _______________feet from each
corner of the building.
A. 2
B. 3
C. 5
D. 6 - ✅✅ B

A minimum of _______________ anchor bolt(s) located _______________ of the
plate section is required to anchor maximum 24-inch-long walls connecting offset
braced wall panels.
A. 1, within the middle third
B. 1, within the middle one-half
C. 2, in the outer one-fourths
D. 2, within 6 inches of each end - ✅✅ A

Unless specifically approved, what is the maximum slump permitted for concrete
placed in removable foundation wall forms?
A. 4 inches

,B. 4 1 /2 inches
C. 5 inches
D. 6 inches - ✅✅ D

Where one coat of complying surface-bonding cement is used as the required
dampproofing over the parging of a masonry foundation wall, the cement coating
must be a minimum of _______________ inch thick.
A. 1 /8
B. 3 /16
C. 1 /4
D. 3 /8 - ✅✅ A

Steel columns used as a part of a foundation system shall be a minimum of
_______________ -inch diameter Schedule 40 pipe size or approved equivalent.
A. 3
B. 3 1 /2
C. 4
D. 5 - ✅✅ A

The continuous vapor barrier required in an unvented crawl space shall extend a
minimum of _______________ inches up the stem wall.
A. 3
B. 4
C. 6
D. 8 - ✅✅ C

A minimum design live load of _______________ shall be used for the
determination of the maximum allowable floor joist spans in attics that are
accessed by a fixed stairway.
A. 10 psf
B. 20 psf
C. 30 psf
D. 40 psf - ✅✅ C

Where 2-inch by 10-inch floor joists of #2 hem-fir are spaced at 16 inches on
center, what is the maximum allowable span where such joists support a sleeping
room and a dead load of 10 psf?
A. 16 feet, 0 inches
B. 16 feet, 10 inches
C. 17 feet, 8 inches

,D. 19 feet, 8 inches - ✅✅ B

Where 2-inch by 10-inch floor joists of #1 spruce-pine-fir are spaced at 16 inches
on center, what is the maximum allowable span where such joists support a living
room and a dead load of 20 psf?
A. 14 feet, 1 inch
B. 15 feet, 5 inches
C. 16 feet, 0 inches
D. 16 feet, 9 inches - ✅✅ A

The International Residential Code is applicable to single-family dwellings a
maximum of _______________ stories in above-grade-plane height.
A. One
B. Two
C. Three
D. Four - ✅✅ C

If there is a conflict in the code between a general requirement and a specific
requirement, the _______________ requirement shall apply.
A. General
B. Specific
C. Least restrictive
D. Most restrictive - ✅✅ B

Provisions of the appendices do not apply unless _______________.
A. Specified in the code
B. Applicable to unique conditions
C. Specifically adopted
D. Relevant to fire or life safety - ✅✅ C

_______________ is the term used in the IRC to describe the individual in charge
of the department of building safety.
A. Building official
B. Code official
C. Code administrator
D. Chief building inspector - ✅✅ A

The building official has the authority to _______________ the provisions of the
code.
A. Ignore

, B. Waive
C. Violate
D. Interpret - ✅✅ D

Used materials may be utilized under which one of the following conditions?
A. They meet the requirements for new materials
B. When approved by the building official
C. Used materials may never be used in new construction
D. A representative sampling is tested for compliance - ✅✅ B

The building official has the authority to grant modifications to the code
_______________.
A. For only those issues not affecting life safety or fire safety
B. For individual cases where the strict letter of the code is impractical
C. Where the intent and purpose of the code cannot be met
D. Related only to administrative functions - ✅✅ B

Unless supporting a surcharge, retaining walls having a maximum height of
__________ inches, measured from the bottom of the footing to the top of the wall,
do not require a permit.
A. 30
B. 36
C. 48
D. 60 - ✅✅ C

Tests performed by _______________ may be required by the building official
where there is insufficient evidence of code compliance.
A. The owner
B. The contractor
C. An approved agency
D. A design professional - ✅✅ C

A permit is not required for the construction of a one-story detached accessory
structure when it has a maximum floor area of _______________ square feet.
A. 100
B. 120
C. 150
D. 200 - ✅✅ D

Written for

Institution
IRC
Course
IRC

Document information

Uploaded on
January 29, 2025
Number of pages
53
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
kharowl Stanford University
Follow You need to be logged in order to follow users or courses
Sold
14
Member since
2 year
Number of followers
7
Documents
1509
Last sold
4 months ago
The Scholar's Depot: Where Knowledge Meets Opportunity

Imagine a digital marketplace buzzing with academic vitality—Kharowl. This knowledgeable entrepreneur curates a treasure trove of meticulously crafted exam materials, sharing a passion for aiding fellow scholars in their academic journeys. Their dedication to excellence shines through every document, fostering a community where knowledge is not just sold but shared.

3.0

2 reviews

5
1
4
0
3
0
2
0
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions