1.2 - ANS-Coefficient for 2 1/2 hose
21 - ANS-Coefficient for 1 1/2 hose
9.5 - ANS-Coefficient for 1 3/4 hose
Coefficient for 1- 2 1/2
1- 3" - ANS-.18
Coefficient for 1- 4"
1-2 1/2 - ANS-.05
Coefficient for 1" - ANS-160
Coefficient for 2-2 1/2 - ANS-.3
Coefficient for 2-3" - ANS-.13
Coefficient for 3- 2 1/2 - ANS-.15
Coefficient for 3" hose - ANS-.52
Coefficient for 4" - ANS-.09
Coefficient for head pressure - ANS-0.434
Cordova guardian foam nozzle - ANS-75
Fog combination handheld master stream
NP - ANS-100
Friction loss for a ground Monitor or triamese - ANS-15
Friction loss for a Siamese or wye - ANS-10
Friction loss for a wildland T - ANS-5
Friction loss for relay or safety factor - ANS-20
Friction loss per hundred for inch and three-quarter starting at 30,60 95,125, 150, 200 -
ANS-1,5,10,15,20,40
Friction loss when pumping a standpipe - ANS-20
Friction loss when pumping a standpipe/ high-rise hose bundle - ANS-100
Friction loss when pumping Arial devices and or FDC - ANS-150
GPM 1 1/2 inch tip LA nozzle - ANS-200
GPM for 1 1/2 inch ranger nozzle - ANS-60
GPM for 1 1/2 tip - ANS-600
GPM for 1 3/4 tip - ANS-815
GPM for 1 7/8 tip - ANS-935
GPM for a 1 1/4 tip - ANS-325
GPM for a 1 1/8 tip - ANS-265
GPM for Helo - ANS-350
Hand line smooth bore tip NP ? - ANS-50
LA 200 high-rise nozzle - ANS-75
Master streams mood for tip NP ? - ANS-80
Psi increase or decrease for the wild-land every 25 feet? - ANS-11
Settings for master stream SOS ( 6 # ) - ANS-150,250,500,750,1000,
1250
Structural per floor psi increase or decrease for elevation - ANS-5