In multi-ply construction, when strip lamination is used to fasten the face ply to the base
ply, the strips of adhesive are spaced - ✔️✔️16" to 24" OC
Wallboard should not be installed in contact with the floor because it - ✔️✔️Wick up
moisture and be damaged
The order in which walls are built can affect a commercial structure's fire rating. The
highest priority would be given to a - ✔️✔️Two-hour fire wall and smoke wall
When calculating drywall requirement, find the needed number of 4'-6" X 8' panels by
dividing the square footage by - ✔️✔️36
When applying a face layer to an office wall in two-ply work, you would most likely use -
✔️✔️3/8" regular drywall
If you are using annular ring nails to install 5/8" drywall, the length of the nail should be
at - ✔️✔️1-3/8"
Nails for drywall application should have heads that are thin at the rim and - ✔️✔️Flat
or concave
For fastening gypsum board to wood framing or furring, the preferred gypsum drywall
screws are Type - ✔️✔️W
In a multi-ply ceiling installation with the framing 24" on center, the recommended screw
spacing for a laminated face ply is - ✔️✔️12" OC
A protective casing that requires no finishing is knows as a(n)_____. - ✔️✔️J-bead
Information about the type and spacing of fasteners along the perimeter and in the field
of gypsum board is provided in the - ✔️✔️Fastening schedule
For making accurate cuts across the narrow dimension of gypsum board, always use -
✔️✔️T-square
The drywall hammer is especially suited for drywall installation because it has -
✔️✔️Convex face
For rigid plastic foam insulation, furring members should be - ✔️✔️Vertically and
spaced 24" on center