ACI- CONCRETE FIELD-TESTING TECHNICIAN - GRADE 1 LATEST EXAM QUESTIONS AND VERIFIED ANSWERS WITH COMPLETE SOLUTIONS GRADED A+ 2025 The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. - Correct Answer 3 in. [75 mm] The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. - Correct Answer 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. - Correct Answer Annually, accuracy The temperature of concrete may be measured in a wheelbarrow. True or False? - Correct Answer True The temperature of concrete may be measured in a wall form. True of False - Correct Answer True