Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

MIC CT Registry Review Updated with Correct and Verified Answers | 2025 LATEST UPDATE. 280 Questions and Correct Answers. 100%

Beoordeling
-
Verkocht
-
Pagina's
23
Cijfer
A+
Geüpload op
20-02-2025
Geschreven in
2024/2025

MIC CT Registry Review Updated with Correct and Verified Answers | 2025 LATEST UPDATE. 280 Questions and Correct Answers. 100%

Instelling
Vak

Voorbeeld van de inhoud

MIC CT Registry Review Updated with
Correct and Verified Answers | 2025
LATEST UPDATE. 280 Questions and
Correct Answers. 100%
CT is commonly referred to as all of the following names EXCEPT

Digital Subtraction angiography

What control does the operator have over the x rays in a CT exam

The energy level and the quantity of x rays can be selected

Which of the following statements is TRUE

kV is the voltage potential between the tube cathode and anode while mA ultimately controls the
filament current and , thus the temperature of the cathode, kV controls the energy level of the x ray
photons and mA controls the number of x ray photons emitted from the tube

Which of the following does Not affect the quantity of x rays that completely penetrates the patient

The type of detector material used

______ made helical imaging possible

Continuous rotation scanners

Which of the following statements is False regarding the collection of CT data

Long scan times are more desirable because they average out motion artifacts

Which of the following is a component NOT normally located in the gantry of a modern CT system

array processor

X rays are used in CT because

they penetrate the body according to specific attenuation characteristics of each tissue

X rays are produced whenever fast moving electrons collide with any form of matter because

The electron loses kinetic energy which is converted into the emission of an x ray photon

Bremsstrahlung radiation does not include which type of electron activity

collision between an incoming electron and an electron in an inner shell of the target atom

Tungsten is used as the target material on the tubes anode because it has a _____ atomic number and a
_______ melting point

,high, high

_____ scanner design was the first to acquire four slices in a single rotation

Multi row detector

The enormous heat the builds up in the CT tube is caused by the

Collision of the electron beam with the tungsten target on the tube anode

The number of electrons that flow from the cathode to the anode in the tube is controlled by the

mA

The slip ring on continous rotation CT scanners

Prevents the high voltage cable from winding up, allows the exam to commence more rapidly,
eliminates the need for the reversal of gantry frame rotation

Which of the following is Not part of the CT tube

collimator

Which of the following are NOt commonly used on todays commercially available CT scanners

xenon detectors, fourth generation technology

Which system component converts the projection attenuation data into the proper digital form for the
array processor

analog to digital converter

X ray photons are produced by a fast moving electron

Colliding with an atomic nucleus, passing close to an atomic nucleus and colliding with an electron in an
atom ejecting it

Which of the following is true regarding solid state detectors

Xray photons cause the detectors to generate a flash of light, they are the detector type used on most
CT scanners today and they can be used in both third generation and fourth generation CT systems

The mA determines the

quantity of x ray photons

Increased ____ will increase the likelihood that a given x-ray will penetrate a material

kV

Collimation

is accomplished by physically blocking x-rays

Scatter radiaiton is caused by

, deflections from the original trajectory of an x ray photon through the patient

Which technology do multirow detectors scanners employ

third generation

Which of the following statements is false regarding the differences between third and fourth
generation scanners

fourth generation scanners are capable of advanced scanning techniques which are impossible on third
generation scanners

Which of the following is true regarding multirow detector CT scanners

The size of the detector arrays along the z direction may be different, the attenuation information from
adjacent detector arrays may be added together to generate thicker slices, all of the detector arrays may
or may not be used

Which of the following is false regarding CT systems

they are limited to non oblique transverse scanning, they cannot generate a straight coronal or sagittal
image, they have no moving parts

Most of the commands from the technologist are received by the ______

system console

The system console may include

Monitor, keyboard, graphic input device.

The patient table ______

may move continuously during the scan

Which of the following statements is false regarding occurrences after an x-ray photon penetrants the
detector aperture

the photon is converted completely into an electron

CT images can be directly scanned in planes other than transverse by:

Orienting the patients body part so that it is not perpendicular to the x-ray beam and tilting the gantry

The Ct xray tube rotates around the poatient

generate projection views at different angles

The cathode filament

helps determine the size of the focal spot

The focal spot size is usually determined by specifying the

slice thickness

Geschreven voor

Vak

Documentinformatie

Geüpload op
20 februari 2025
Aantal pagina's
23
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$14.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ACADEMICAIDSTORE Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1214
Lid sinds
4 jaar
Aantal volgers
892
Documenten
12031
Laatst verkocht
1 week geleden
ACADEMICAID STORE

Welcome to ACADEMICAID store! We specialize in reliable test banks, exam questions with verified answers, practice exams, study guides, and complete exam review materials to help students pass on the first try. Our uploads support Nursing programs, professional certifications, business courses, accounting classes, and college-level exams. All documents are well-organized, accurate, exam-focused, and easy to follow, making them ideal for quizzes, midterms, finals, ATI & HESI prep, NCLEX-style practice, certification exams, and last-minute reviews. If you’re looking for trusted test banks, comprehensive exam prep, and time-saving study resources, you’re in the right place.

Lees meer Lees minder
4.1

176 beoordelingen

5
98
4
29
3
28
2
6
1
15

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen