The ____ shall be responsible for the maintenance of fuel gas installations. - ANSWERowner or owner agents- 102.3 Maintenance If the permit has not been issued, an application for a permit is considered abandoned _____ days after the date of filing. - ANSWER180 days-106.3.2 Time limitation of application The lowest portion of a floor furnace shall have 12 inch minimum clearance on all sides except the control side, which shall have a ____ minimum clearance. - ANSWER18-609.4 Clearance Water heaters utilized both to supply potable water and provide hot water for space heating shall be listed and labeled and shall be installed in accordance with the _____. - ANSWERI.P.C. International Plumbing code- 624.2 Water heaters used for space heating A drip shall not be be located where condensate is subject to ____. - ANSWERFreezing-408.3 Location of drips A means to interrupt the electrical supply to an air conditioning appliance shall be provided ____ and not more than ___ feet from the air conditioner. - ANSWERWithin Sight and 50 feet- 627.10 switches in electrical supply Floor furnaces shall not be installed _____ - ANSWERin a concrete floor built on grade.-609.2 #4 Placement A yellow insulated copper tracer wire or other approved conductor shall be installed ____ to the underground nonmetallic gas piping. - ANSWERAdjacent-404.15.3 tracer The floor register of a floor furnace is permitted to be installed ____ - ANSWER12 inches from the draperies-609.2 #3 placement Casing extension boots shall not be installed on a wall furnace unless __ - ANSWERlisted as a part of the appliance.-608.5 ducts prohibited Outside ventilation air shall be supplied to the space containing a recirculating direct fired industrial heater at a minimum rate of _ com per 1,000 but/h of the rated input of the heater. - ANSWER4-612.5 air supply Clothes dryer exhaust ducts shall be equipped with a ___ - ANSWERbackdraft damper- 614.4 exhaust installation Vented wall furnaces shall be located so as not to cause a ___ to walls floors combustible furnishings or doors. - ANSWERfire hazard- 608.3 location Non recirculating direct fired industrial air heaters shall not be used to supply any area containing ___ - ANSWERsleeping quarters-611.2 installation dryer exhaust systems shall be independent of all other systems and shall convey the moisture and any products of combustion to the - ANSWERoutside of the building 614.1 installation dryer ducts shall not be connected or installed with ___ or other fasteners that will obstruct the flow. - ANSWERsheet metal screws 614.4 exhaust installation where space for a domestic clothes dryer is provided an ______ system shall be installed - ANSWERexhaust duct 614.6.7 exhaust duct required the minimum unobstructed total area of the outside and return air ducts or openings to a forced air warm air furnace shall be not less than __ square inches per 1,000 btu/h output rating capacity of the furnace - ANSWER2-618.2 forced air furnaces in general return air for a forced air furnace shall not be taken from a ____ - ANSWERCrawl space-618.5 #7 prohibited sources the required ventilation opening to a sauna room shall not be less than _ inches by _ inches - ANSWER4 and 8- 615.7 sauna room suana heaters shall be equipped with a thermostat that limits the room temp to no more than ___ degrees Fahrenheit - ANSWER194 degrees-615.6 heat and time controls required outdoor air inlets for a residential forced air heating system shall be covered with screen having _ inch openings - ANSWER1/4 inch-618.6 screen Appliances regulated by this code shall be ___ and ___ for the application in which they are used unless otherwise approved in accordance with section 105 - ANSWERlisted and labeled-301.3 listed and labeled the minimum dimension of openings for indoor or outdoor combustion air shall be not less _ inches. - ANSWER3 inches(304.5.3.1)(304.6) the highest end of the scale for mechanical gauges used to measure test pressures must not be greater than __ times the test pressure. - ANSWER5 times(406.4)testpressuremeasurment a gas piping system located inside an ____- building is limited to a maximum design operating pressure of 5 pounds per square inch gage. - ANSW

Show more Read less
Institution
ALABAMA GAS
Course
ALABAMA GAS

Content preview

ALABAMA GAS TEST QUESTIONS &
ANSWERS 100% CORRECT!!
The ____ shall be responsible for the maintenance of fuel gas installations. -
ANSWERowner or owner agents- 102.3 Maintenance

If the permit has not been issued, an application for a permit is considered
abandoned _____ days after the date of filing. - ANSWER180 days-106.3.2 Time
limitation of application

The lowest portion of a floor furnace shall have 12 inch minimum clearance on all
sides except the control side, which shall have a ____ minimum clearance. -
ANSWER18-609.4 Clearance

Water heaters utilized both to supply potable water and provide hot water for space
heating shall be listed and labeled and shall be installed in accordance with the
_____. - ANSWERI.P.C. International Plumbing code- 624.2 Water heaters used for
space heating

A drip shall not be be located where condensate is subject to ____. -
ANSWERFreezing-408.3 Location of drips

A means to interrupt the electrical supply to an air conditioning appliance shall be
provided ____ and not more than ___ feet from the air conditioner. - ANSWERWithin
Sight and 50 feet- 627.10 switches in electrical supply

Floor furnaces shall not be installed _____ - ANSWERin a concrete floor built on
grade.-609.2 #4 Placement

A yellow insulated copper tracer wire or other approved conductor shall be installed
____ to the underground nonmetallic gas piping. - ANSWERAdjacent-404.15.3
tracer

The floor register of a floor furnace is permitted to be installed ____ - ANSWER12
inches from the draperies-609.2 #3 placement

Casing extension boots shall not be installed on a wall furnace unless __ -
ANSWERlisted as a part of the appliance.-608.5 ducts prohibited

Outside ventilation air shall be supplied to the space containing a recirculating direct
fired industrial heater at a minimum rate of _ com per 1,000 but/h of the rated input
of the heater. - ANSWER4-612.5 air supply

Clothes dryer exhaust ducts shall be equipped with a ___ - ANSWERbackdraft
damper- 614.4 exhaust installation

,Vented wall furnaces shall be located so as not to cause a ___ to walls floors
combustible furnishings or doors. - ANSWERfire hazard- 608.3 location

Non recirculating direct fired industrial air heaters shall not be used to supply any
area containing ___ - ANSWERsleeping quarters-611.2 installation

dryer exhaust systems shall be independent of all other systems and shall convey
the moisture and any products of combustion to the - ANSWERoutside of the
building 614.1 installation

dryer ducts shall not be connected or installed with ___ or other fasteners that will
obstruct the flow. - ANSWERsheet metal screws 614.4 exhaust installation

where space for a domestic clothes dryer is provided an ______ system shall be
installed - ANSWERexhaust duct 614.6.7 exhaust duct required

the minimum unobstructed total area of the outside and return air ducts or openings
to a forced air warm air furnace shall be not less than __ square inches per 1,000
btu/h output rating capacity of the furnace - ANSWER2-618.2 forced air furnaces

in general return air for a forced air furnace shall not be taken from a ____ -
ANSWERCrawl space-618.5 #7 prohibited sources

the required ventilation opening to a sauna room shall not be less than _ inches by _
inches - ANSWER4 and 8- 615.7 sauna room

suana heaters shall be equipped with a thermostat that limits the room temp to no
more than ___ degrees Fahrenheit - ANSWER194 degrees-615.6 heat and time
controls

required outdoor air inlets for a residential forced air heating system shall be covered
with screen having _ inch openings - ANSWER1/4 inch-618.6 screen

Appliances regulated by this code shall be ___ and ___ for the application in which
they are used unless otherwise approved in accordance with section 105 -
ANSWERlisted and labeled-301.3 listed and labeled

the minimum dimension of openings for indoor or outdoor combustion air shall be not
less _ inches. - ANSWER3 inches(304.5.3.1)(304.6)

the highest end of the scale for mechanical gauges used to measure test pressures
must not be greater than __ times the test pressure. - ANSWER5
times(406.4)testpressuremeasurment

a gas piping system located inside an ____- building is limited to a maximum design
operating pressure of 5 pounds per square inch gage. -
ANSWERinstitutional(402.6)#3Maximujmdesignoperatingpressure

, when a union is provided for an appliance connected by rigid metallic pipe, the union
shall be accessible and located within _ feet of the appliance - ANSWER6
feet(411.1.6)Unions

fuel gas piping for other than day gas conditions shall be sloped not less than __
inch in 15 feet to prevent traps - ANSWER1/4 inch(408.1)slopes

to allow connection of a pressure measuring instrument a tee fitting with one capped
opening shall be installed not more than __ pipe diameters downstream of an mp
regulator - ANSWER10 pipe diameters(410.2)#6MPregulatos

a dedicated gas shut off valve must be located adjacent to the egress door of a
laboratory having __ or more fuel gas outlets -
ANSWER2(409.6)shutoffvalveforlaboratories

semirigid metallic tubing used to connect a gas appliance shall not exceed __ feet in
length - ANSWER6 feet(411.1)#3Connectingapplaince

the appliance shutoff valve is permitted to be installed at a manifold that is not
greater than _____ from the appliance - ANSWER50 feet(409.5.3)Locatedatmanifold

a gas shut off valve complying with ____ is permitted on 5 psig pressure gas lines
without requiring 5 g label - ANSWERasme
b16.33(Table409.1.1)ManualGasValveStandards

a gas shut off valve shall be located within ___ of the appliance - ANSWER6
feet(409.5.1)locatedwithingthesameroom

self service lp gas dispensing systems for motor vehicles require an emergency shut
off switch located at least 20 feet and not greater than __ from the lp gas dispensing
equipment - ANSWER100 feet(412.8)Privatefuelingofmotorvehicles

where there are multiple meters the ___ must mark the piping system supplied by
each meter with an approved permanent identification -
ANSWERinstaller(401.7)Pipingmeteridentification

the volume of gas to be provided must be determined directly from the ___ of
appliance served - ANSWERinput rating(402.2Maximumgasdemand)

in liquefied pertoleum gas motor vehicle fuel dispensing facilities the hose length
shall not exceed ___ - ANSWER18 feet(412.7.2)Hoses

gas piping supports 1/2 inch copper tubing shall be spaced no more then __ -
ANSWER4 feet apart(415.1)chartintervalofsupport

sediment traps are not required for ____ - ANSWERranges(408.4)Sedimenttrap

the maximum amount of gas input required per unit of time usually expressed in
cubic feet per hour or btu/h (1 btu/h=0.2931 w) - ANSWERdemand(202)GenDef

Written for

Institution
ALABAMA GAS
Course
ALABAMA GAS

Document information

Uploaded on
February 21, 2025
Number of pages
26
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$16.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersbyjol West Virginia
Follow You need to be logged in order to follow users or courses
Sold
446
Member since
3 year
Number of followers
254
Documents
14151
Last sold
1 week ago

3.7

78 reviews

5
29
4
20
3
18
2
2
1
9

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions