Where a minimum of 12" of cover cannot be provided, the pipe shall be
installed in a ______ or be "bridged" (shielded). - ANSWER--conduit
Gas piping in contact with earth or other corroding material, the piping
shall be protected against _________ in an approved manner -
ANSWER--corrosion
where dissimilar metals are joined underground, an ______ ________ or
_____ shall be used. - ANSWER--insulating coupling or fitting
Piping shall not be laid in contact with _______. - ANSWER--cinders
Uncoated thread or socket welded joints shall not be used in piping in
contact with ______ or where internal or external crevice corrosion is
known to occur. - ANSWER--soil
Where the formation hydrates or ice is known to occur, piping shall be
protected against ______. - ANSWER--freezing
underground piping, where installed through the outer foundation or
basement wall of a building, shall be __________ and the space between
, NATIONAL FUEL GAS CODE EXAM NEWEST 2025
ACTUAL EXAM COMPLETE 200 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS)
|ALREADY GRADED A+
the gas piping and the building shall be sealed to prevent the entry of
_________. - ANSWER--encased in a protective pipe; gas or water.
piping underground, beneath buildings shall be ___________. -
ANSWER--encased in an approved conduit.
(installed in accordance with 7.1.6.1 or 7.1.6.2).
conduit installed underground, beneath buildings shall extend at least
____ inches outside the building; be _____ outdoors above grade, and be
installed so as to prevent the entrance of ______ and _____. -
ANSWER--4; vented; water and insects.
plastic pipe shall be installed ______ and ________ only. - ANSWER--
outdoors ; underground
plastic pipe shall be permitted to terminate above grade where an
________ is used. - ANSWER--anodeless riser
connections between metallica and plastic piping outdoors and
underground shall be made with fittings conforming to ________ or
___________. - ANSWER--ASTM D 2513; ASTM F 1973
, NATIONAL FUEL GAS CODE EXAM NEWEST 2025
ACTUAL EXAM COMPLETE 200 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS)
|ALREADY GRADED A+
Tracer wire of _____ AWG or tape shall be buried with the plastic pipe
to facilitate locating. One end shall be brought aboveground at a
building wall or riser. - ANSWER--14
Gas piping to be sloped ___" for every ____' to prevent traps. -
ANSWER--1/4; 15
3/4" or 1" steel pipe shall be supported every ___'. - ANSWER--8
where gas piping is to be concealed, _____, tubing fittings, right and left
couplings, bushings, swing joints and compression couplings shall not
be used - ANSWER--unions
where copper tubing installed vertically and horizontally inside hollow
walls without protection, a steel striker barrier not less than ________ or
________ " thick or equivalent shall be installed between tubing and
finished wall. - ANSWER--1.3mm or .0508".
In industrial occupancies, gas pipe in solid floors such as concrete shall
be laid in _______ in the floor and covered to permit access to pipe with
minimum damage to the building structure. - ANSWER--channels
In other than indstrial occupancies where approved by the AHJ, gas pipe
embedded in concrete floor slabs made of portland cement shall be
, NATIONAL FUEL GAS CODE EXAM NEWEST 2025
ACTUAL EXAM COMPLETE 200 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS)
|ALREADY GRADED A+
surrounded with a minimum of ____" of concrete, protected from
corrosion, and not embedded in concret made with quickset additives or
cinder aggregate. - ANSWER--1 1/2"
gas piping with fuel gas lighter than air, exceeding 5 psi, and installed in
vertical chases: shall be installed with a pressure regulator accessible for
service or repair and equipped with a vent limiting device and shall be
allowed to vent _______________ . - ANSWER--directly into the chase
gas piping with fuel gas lighter than air, exceeding 5psi and installed in
vertical chases, shall be installed with a pressure regulator accessible for
service or repair and vented __________; ______________. -
ANSWER--directly to the outdoors ; or to a point within the top 1' of the
chase.
Where fuel gas is heavier than air, exceeding 5psi and installed in
vertical chases, shall be installed with a pressure regulator accesible for
service or repair and vented _________. - ANSWER--only directly to
the outdoors.
chases used for gas regulator venting, shall be ventilated to the outdoors
and only at the top. The openings shall have a minimum free area in
square inches equal to the product of ______ of the maximum pressure
in the piping in psi times the largest nominal diameter of that piping in
inches, or cross sectional of the chase, whichever is smaller. Where