U3 ICC Tank Tightness Testing Exam QUESTIONS
WITH COMPLETE 100% VERIFIED SOLUTIONS
2024/2025
On a steel tank without cathodic protection, if a coating is flawed, what happens at the
flaw?
a. Cathodic surface is increased
b. Current flow is increased from this area
c. Current flow is increased to this area - Answer - b. Current flow is increased from this
area

On an impressed current cathodic protection system, the negative wire of the rectifier is
connected to the:
a. Anode
b. Cathode
c. Drop tube
d. Dielectric union - Answer - b. Cathode

All are examples of acceptable release detection for tanks, except:
a. Impressed current cathodic protection
b. Automatic tank gauging
c. Statistical inventory reconciliation
d. Soil-vapor monitoring - Answer - a. Impressed current cathodic protection

When a tank is temporarily closed, the cathodic protection system:
a. Must be turned off
b. Must remain in operation
c. Should be removed
d. Operator can have it on or off. - Answer - b. Must remain in operation

When a steel tank is installed with a galvanic CP system attached, the tank gauges are
usually connected through a riser with a dielectric bushing. What is the purpose of that?
a. To prevent static discharge
b. To minimize effects of noise
c. To electrically isolate the tank from the tank gauge
d. To prevent water intrusion in the tank - Answer - c. To electrically isolate the tank
from the tank gauge

Factory-installed diectric coatings may include all of the following except:

, a . Asphalt
b. epoxies
c. Enamels
d. fiberglass-reinforced plastic - Answer - a . Asphalt

According to the EPA, Tank tightness test data must be maintained for:
a. 18 months
b. 3 years
c. 5 years
d. Until the next test is performed - Answer - d. Until the next test is performed

How long must records of UST system repairs be available on site?
a. 60 days
b. 1 year
c. 5 years
d. for the remaining lifetime of the UST system - Answer - d. for the remaining lifetime
of the UST system

In the event of a release, what is the reporting requirement?
a. ICC licensed supervisor must report the leak within 24 hours
b. Owner/Operator must report the leak within 24 hours
c. Owner/Operator must report the leak within 18 hours
d. ICC licensed supervisor must report the leak within 18 hours - Answer - b.
Owner/Operator must report the leak within 24 hours

At what size spill does it need to be reported?
a. 5 gallons
b. 10 gallons
c. 15 gallons
d. 25 gallons - Answer - d. 25 gallons

Contamination of soils is encountered before removing a tank. The clean up must be
initiated by the:
a. Fire Marshal
b. Ecology inspector
c. Owner / operator of the UST system
d. Landlord - Answer - c. Owner / operator of the UST system

All are examples of overfill protection, except:
a. Vent restricting device

Geschreven voor

Vak

Documentinformatie

Geüpload op
23 februari 2025
Aantal pagina's
10
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$9.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
mkhenris

Maak kennis met de verkoper

Seller avatar
mkhenris Self
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
1 jaar
Aantal volgers
0
Documenten
13
Laatst verkocht
10 maanden geleden
Lecthenris

EXCELSIOR! Am dedicated with a passion for helping students succeed, I specialize in providing high-quality study resources on STUVIA including ATI modules and other essential certifications, earning excellent ratings and a stellar reputation for boosting students' grades. My commitment to excellence

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen