Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

IIDA Chapters 7-10 Practice Test (Answered) 175 Questions and Correct Answers, 100% Correct. 2025/2026.

Beoordeling
-
Verkocht
-
Pagina's
30
Cijfer
A+
Geüpload op
28-02-2025
Geschreven in
2024/2025

IIDA Chapters 7-10 Practice Test (Answered) 175 Questions and Correct Answers, 100% Correct. 2025/2026. LEED is sponsored by a. NIBS. b. USGBC. c. ASHRAE. d. CSI. b The lobby of a building from the stair enclosure to the exterior door is called: a. exit passageway. b. exit access. c. exit discharge. d. exit refuge. c There are a number of considerations that are important in designing a safe and accessible residential bathroom. Which of the following is NOT a consideration? a. There should be at least 48 inches of clear space in front of a lavatory. b. Ground fault circuit interrupters must be specified on all receptacles. c. A mechanical ventilation system must be provided. d. The minimum clearance from the center of the toilet to any obstruction is 16-18 inches, minimum. c

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

IIDA Chapters 7-10 Practice Test
(Answered) 175 Questions and Correct
Answers, 100% Correct. 2025/2026.
LEED is sponsored by
a. NIBS.
b. USGBC.
c. ASHRAE.
d. CSI.

b

The lobby of a building from the stair enclosure to the exterior door is called:
a. exit passageway.
b. exit access.
c. exit discharge.
d. exit refuge.

c

There are a number of considerations that are important in designing a safe and accessible
residential bathroom. Which of the following is NOT a consideration?

a. There should be at least 48 inches of clear space in front of a lavatory.
b. Ground fault circuit interrupters must be specified on all receptacles.
c. A mechanical ventilation system must be provided.
d. The minimum clearance from the center of the toilet to any obstruction is 16-18 inches, minimum.

c

What combination of combustible and non-combustible trim and decorations are permissible in
occupancies A, E, I, R-1 and R-2?

a. noncombustible 10%, combustible 5%
b. noncombustible unlimited, combustible 10%
c. noncombustible 20%, combustible 20%
d. noncombustible 10%, combustible 30%

b

Which of the following wall and partition assemblies is INCORRECT with respect to the indicated fire
rating?

a. wood 2x4 studs, 5/8" gypsum plaster on metal lath each side, 5 1/4" face-to-face thickness = 1
hour fire resistance rating
b. noncombustible metal studs, two layers of 1/2" Type-X gypsum lath each side, 3 5/8" face-to- face
thickness = 2 hour fire resistance rating
c. noncombustible metal studs, 5/8" gypsum plaster on metal lath each side, 4 3/4" face-to-face

,thickness = 2 hour fire resistance rating
d. wood 2x4 studs, 5/8" Type-X gypsum wallboard each side, 4 3/4" face-to-face thickness = 1 hour
fire resistance rating

c

Safety glass is required in which of the following conditions?

a. glazing in swinging doors, storm doors, or when the bottom edge of the pane is less than 18"
above the door
b. glazing in showers and bathtubs or when the pane is greater than 8 sf (9sf)
c. sidelites 30" (24") from a door frame and 60" above the floor
d. glazing in unframed swinging doors or when the pane is greater than 6 sf

a

The Life Safety Code has been developed by the National Fire Protection Association and is specific
in the following areas:

a. egress facilities, fire-protection equipment, smoke control, sprinklers
b. fire-protection equipment, smoke control, egress facilities
c. interior finishes, egress facilities, fire-protection equipment, smoke control
d. all of the above

d

The principle test used to determine both the flame spread and smoke development ratings
for building materials and interior finishes is the:
a. radiant panel test
b. Steiner tunnel test
c. corner test
d. CAL 133

b

Which of the following tests are associated with vinyl wallcovering?

a. ASTM E-84 Steiner Tunnel test
b. Methenamine Pill test
c. the Chamber test
d. the Radiant Panel test

a

Egress doorways shall have minimum clear and free width of __ and a maximum door leaf of __.
a. 30" and 36" respectively
b. 32" and 36" respectively
c. 32" and 48" respectively
d. 36" and 38" respectively

c

, When calculating floor area of a building for egress considerations, which is included in the net floor
area of the building?

a. corridors
b. toilet rooms
c. kitchens
d. stairways

c

Which is not considered part of the main egress system?

a. exit access
b. exit enclosure
c. exit
d. exit discharge

b

What is one of the most commonly used flammability tests for building construction, such as wall
and ceiling assemblies?

a. UL
b. NFPA 358
c. ASTM E-84
d. ASTM E-119

d

When discussing building limitations in the building code, the issue of "protected" and
"unprotected" is often a source of confusion. "Protected" means:

a. the building uses an automatic sprinkler system
b. mill construction or heavy timers are used
c. a fire wall or party wall has been used
d. the structural elements of the building have been treated to increase their fire
resistance

d

When completing an interior design furniture plan, it is important to give consideration to any
furnishings that could come close to the sprinkler heads of the building. The codes require that any
panels or furnishings be at least ___ away from the sprinkler head deflectors.

a. 9 inches
b. 12 inches
c. 15 inches
d. 18 inches

d

Geschreven voor

Vak

Documentinformatie

Geüpload op
28 februari 2025
Aantal pagina's
30
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$16.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
LectDan Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
221
Lid sinds
3 jaar
Aantal volgers
157
Documenten
7993
Laatst verkocht
1 week geleden

4.0

48 beoordelingen

5
25
4
12
3
2
2
4
1
5

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen