2SXO SUPPLY VOL 4 Exam Questions With
Solved Solutions
Which item is not checked when off-loading property from a carrier? -
ANSWER>>Production date
Who works with the in-checker to ensure items are correctly identified and the
appropriate condition tags or labels are used on the assets? - ANSWER>>inspector
Which block of the AF Form 2005 will the inspector sign or stamp after the in-
checker has signed and dated the form? - ANSWER>>Block B
Which operation includes verifying identity, security classification, condition,
status, markings, tagging, and labeling for property? - ANSWER>>Inspection
operations
Who is responsible for overseeing care of supply (COSIS) program -
ANSWER>>Chief inspector
What three things are used to identify an item - ANSWER>>Reference number,
stock number, and item description
Which department of defense (DD) form is red and is used to identify property
that is unserviceable and uneconomical to repair - ANSWER>>DD Form 1577,
Unserviceable (Condemned) Tag
What is the purpose of the department of defense (DD) for 2477 inspection
extension - ANSWER>>Updates inspection data
What TRIC is processed to initiate a condition change? - ANSWER>>TRIC FCC
, An organization refusal would be a customers responsibility if the -
ANSWER>>Customer failed to cancel the due out
Who schedules and accomplishes an aggressive surveillance inspection program
of all items in storage? - ANSWER>>inspector
When is a supply discrepancy report (SDR) required - ANSWER>>Incorrect
materiel, unacceptable substitutes, or duplicate shipments.
Where are all unresolved supply discrepancy reports forwarded when additional
help is needed? - ANSWER>>Major Command (MAJCOM)
At what temperature must a refrigerated storage chill space be maintained -
ANSWER>>Between 32 and 50°F.
At a minimum how many feet must separate flammable storage facilities from
other facilities - ANSWER>>50 feet
What is a major disadvantage in the use of unimproved open storage -
ANSWER>>Limited use of materiel handling equipment (MHE).
The basic recourse of any materiel management and distribution operation is the
- ANSWER>>Storage space
What must be planned before the actual start of the storage operation to assure
the floor and cubic capacity of the warehouse will be used to the greatest extent
possible? - ANSWER>>storage areas
When you increase the amount of space for an item in a location to eliminate
overflow into another item's location, you are implementing what storage factor?
- ANSWER>>Item quantity
Solved Solutions
Which item is not checked when off-loading property from a carrier? -
ANSWER>>Production date
Who works with the in-checker to ensure items are correctly identified and the
appropriate condition tags or labels are used on the assets? - ANSWER>>inspector
Which block of the AF Form 2005 will the inspector sign or stamp after the in-
checker has signed and dated the form? - ANSWER>>Block B
Which operation includes verifying identity, security classification, condition,
status, markings, tagging, and labeling for property? - ANSWER>>Inspection
operations
Who is responsible for overseeing care of supply (COSIS) program -
ANSWER>>Chief inspector
What three things are used to identify an item - ANSWER>>Reference number,
stock number, and item description
Which department of defense (DD) form is red and is used to identify property
that is unserviceable and uneconomical to repair - ANSWER>>DD Form 1577,
Unserviceable (Condemned) Tag
What is the purpose of the department of defense (DD) for 2477 inspection
extension - ANSWER>>Updates inspection data
What TRIC is processed to initiate a condition change? - ANSWER>>TRIC FCC
, An organization refusal would be a customers responsibility if the -
ANSWER>>Customer failed to cancel the due out
Who schedules and accomplishes an aggressive surveillance inspection program
of all items in storage? - ANSWER>>inspector
When is a supply discrepancy report (SDR) required - ANSWER>>Incorrect
materiel, unacceptable substitutes, or duplicate shipments.
Where are all unresolved supply discrepancy reports forwarded when additional
help is needed? - ANSWER>>Major Command (MAJCOM)
At what temperature must a refrigerated storage chill space be maintained -
ANSWER>>Between 32 and 50°F.
At a minimum how many feet must separate flammable storage facilities from
other facilities - ANSWER>>50 feet
What is a major disadvantage in the use of unimproved open storage -
ANSWER>>Limited use of materiel handling equipment (MHE).
The basic recourse of any materiel management and distribution operation is the
- ANSWER>>Storage space
What must be planned before the actual start of the storage operation to assure
the floor and cubic capacity of the warehouse will be used to the greatest extent
possible? - ANSWER>>storage areas
When you increase the amount of space for an item in a location to eliminate
overflow into another item's location, you are implementing what storage factor?
- ANSWER>>Item quantity