Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

JOURNEYMAN ELECTRICIAN PRACTICE TEST|| 50 ACTUAL QUESTIONS WITH VERIFIED SOLUTION 2025|| RATED A+

Beoordeling
-
Verkocht
-
Pagina's
12
Cijfer
A+
Geüpload op
14-03-2025
Geschreven in
2024/2025

JOURNEYMAN ELECTRICIAN PRACTICE TEST|| 50 ACTUAL QUESTIONS WITH VERIFIED SOLUTION 2025|| RATED A+ 1. Conductors with marked on the insulation are NOT approved for use in a wet location.: THHN conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. 2. Given: A one-family dwelling unit with a demand load of 200 amperes is sup- plied with a 120/240 volt, single-phase, electrical system from the local utility company. What is the MINIMUM size aluminum THW conductors required for use as service-entrance conductors for this residence?: 4/0 AWG one-family dwelling 120/240 volt, single-phase, service-entrance conductors to be sized at an ampacity of not less than 83% of the service rating. Therefore, 200 amperes x 83% = 166 amperes; size 4/0 AWG THW aluminum conductors with an allowable ampacity of 180 amperes should be selected for this dwelling. 3. Where a 150 kVA, single-phase transformer having a secondary voltage of 120/240 is installed at a multi-family dwelling, the full-load current rating, in amperes, of the secondary is .: 625 amperes

Meer zien Lees minder
Instelling
Master Electrical
Vak
Master Electrical

Voorbeeld van de inhoud

1. Conductors with marked on the insulation are NOT approved for use
in a wet location.: THHN

conductors with THHN insulation are approved for use in dry and damp locations
only and conductors with THWN, THHW, and THW insulation are recognized for use
in dry and wet locations.
2. Given: A one-family dwelling unit with a demand load of 200 amperes is sup-
plied with a 120/240 volt, single-phase, electrical system from the local utility
company. What is the MINIMUM size aluminum THW conductors required for
use as service-entrance conductors for this residence?: 4/0 AWG

one-family dwelling 120/240 volt, single-phase, service-entrance conductors to be
sized at an ampacity of not less than 83% of the service rating. Therefore, 200
amperes x 83% = 166 amperes; size 4/0 AWG THW aluminum conductors with an
allowable ampacity of 180 amperes should be selected for this dwelling.
3. Where a 150 kVA, single-phase transformer having a secondary voltage of
120/240 is installed at a multi-family dwelling, the full-load current rating, in
amperes, of the secondary is .: 625 amperes

To find the full-load current rating of the single-phase transformer apply the sin-
gle-phase current formula as shown:I = (150 kVA x 1000) / 240 volts = 15,000/240
= 625 amperes
4. Which one of the following listed circuit breakers is NOT a standard ampere
rating?: 75 amperes

the standard ampere ratings for fuses and circuit breakers. A circuit breaker with an
ampere rating of 75 amperes is not a standard ampere rating.
5. The MINIMUM length of free conductor to be left at each junction box for
the purpose of splicing conductors, or making connections to illuminares or

, devices shall be .: 6 inches

free conductor is to be left at each junction box for splices or the connection of
luminaires or devices. The intent of this rule is to ensure enough conductor slack for
the terminal connections or splices to be made easily.
6. In general, overhead service-drop conductors shall NOT be smaller than
.: 8 AWG copper

overhead service-drop conductors to be not smaller than 8 AWG copper or 6
AWG aluminum or copper-clad aluminum. Do not get service-drop conductors, the

Geschreven voor

Instelling
Master Electrical
Vak
Master Electrical

Documentinformatie

Geüpload op
14 maart 2025
Aantal pagina's
12
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$14.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
MBOFFIN HOWARD COMMUNITY COLLEGE
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
725
Lid sinds
4 jaar
Aantal volgers
218
Documenten
5498
Laatst verkocht
3 dagen geleden
TUTOR MBOFFIN STORES.

3.7

122 beoordelingen

5
53
4
20
3
24
2
9
1
16

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen