1101.1 Scope correct answers The Provisions of this chapter shall govern the materials, design, construction, and installation of storm drainage 1101.2 Where required correct answers All roofs, paved areas, yards, courts, and courtyards in buildings shall drain into a separate storm sewer system or a combined sewer system or to an approved place of disposal. 1101.3 Prohibited drainage correct answers Storm water shall not be drained into sewers intended for sewage only 1101.4 Tests correct answers The conductors and the building storm drain shall be tested in accordance with Section 312 1101.5 Change in size correct answers The size of a drainage pipe shall not be reduced in the direction of flow 1101.6 Fittings and connections correct answers All connections and changes in direction of the storm drainage system shall be made with approved drainage type fittings in accordance with Table 706.3. The fittings shall not obstruct or retard flow in the system. 1101.7 Roof Design correct answers Roofs shall be designed for the maximum possible depth of water that will pond there on as a determined by the relative levels of roof deck and overflow weirs, scuppers, edges, or serviceable drains in combination with the deflected structural elements. In determining the maximum possible depth of water, all primary roof drainage means shall be assumed to be blocked 1101.8 Cleanouts required correct answers Cleanouts shall be installed in the storm drainage system and shall comply with the provisions of this code for sanitary drainage pipe cleanouts 1101.9 Backwater valves correct answers Storm drainage systems shall be provided with backwater valves as required for sanitary drainage systems in accordance with Section 715 1102.1 General correct answers The materials and methods utilized for the construction and installation of storm drainage systems shall comply with this section and applicable provisions of Chapter 7 1102.2 Inside storm drainage conductors correct answers Inside storm drainage conductors installed above ground shall conform to on e of the standards listed in Table 702.2 1102.3 Underground building storm drain pipe correct answers Underground building storm drain pipe shall conform to one of the standards listed in Table 702.2 1102.4 Building storm sewer pipe correct answers Building storm sewer pipe shall conform to one o the standards listed in Table 1102.4 (Look at table on page 2 in notes)

Show more Read less
Institution
Plumbing Code
Course
Plumbing code

Content preview

Plumbing code (Storm/Roof Drains) || Already Passed.
1101.1 Scope correct answers The Provisions of this chapter shall govern the materials, design,
construction, and installation of storm drainage

1101.2 Where required correct answers All roofs, paved areas, yards, courts, and courtyards in
buildings shall drain into a separate storm sewer system or a combined sewer system or to an
approved place of disposal.

1101.3 Prohibited drainage correct answers Storm water shall not be drained into sewers
intended for sewage only

1101.4 Tests correct answers The conductors and the building storm drain shall be tested in
accordance with Section 312

1101.5 Change in size correct answers The size of a drainage pipe shall not be reduced in the
direction of flow

1101.6 Fittings and connections correct answers All connections and changes in direction of the
storm drainage system shall be made with approved drainage type fittings in accordance with
Table 706.3. The fittings shall not obstruct or retard flow in the system.

1101.7 Roof Design correct answers Roofs shall be designed for the maximum possible depth of
water that will pond there on as a determined by the relative levels of roof deck and overflow
weirs, scuppers, edges, or serviceable drains in combination with the deflected structural
elements. In determining the maximum possible depth of water, all primary roof drainage means
shall be assumed to be blocked

1101.8 Cleanouts required correct answers Cleanouts shall be installed in the storm drainage
system and shall comply with the provisions of this code for sanitary drainage pipe cleanouts

1101.9 Backwater valves correct answers Storm drainage systems shall be provided with
backwater valves as required for sanitary drainage systems in accordance with Section 715

1102.1 General correct answers The materials and methods utilized for the construction and
installation of storm drainage systems shall comply with this section and applicable provisions of
Chapter 7

1102.2 Inside storm drainage conductors correct answers Inside storm drainage conductors
installed above ground shall conform to on e of the standards listed in Table 702.2

1102.3 Underground building storm drain pipe correct answers Underground building storm
drain pipe shall conform to one of the standards listed in Table 702.2

1102.4 Building storm sewer pipe correct answers Building storm sewer pipe shall conform to
one o the standards listed in Table 1102.4 (Look at table on page 2 in notes)

, 1102.5 Subsoil drain pipe correct answers Subsoil drains shall be open-jointed, horizontally split
or perforated pipe conforming to one of the standards listed in Table 1102.5 (Table on page 3 in
notes)

1102.6 Roof Drains correct answers Roof drains shall conform to ASME A112.21.2 M or ASME
A112.3.1

1102.7 Fittings correct answers Pipe fittings shall be approved for installation with the piping
material installed, and shall conform to the respective pipe s standards or one of the standards
listed in Table 1102.7. The fittings shall not have ledges, shoulders, or reductions capable of
retarding or obstructing flow in the piping. Threaded drainage pipe fittings shall be of the
recessed drainage type.

1103.1 Main Trap correct answers Leaders and storm drains connected to a combined sewer
shall be trapped. Individual storm water traps shall be installed on the storm water drain branch
serving each conductor, or a single trap shall be installed in the main storm drain just before its
connection with the combined building sewer or the public sewer

1103.2 Material correct answers Storm water traps shall be of the same materials as the piping
system to which they are attached

1103.3 Size correct answers Traps for individual conductors shall be the same size as the
horizontal drain to which they are connected

1103.4 Cleanout correct answers An accessible cleanout shall be installed on the building side of
the trap

1104.1 Prohibited Use correct answers Conductor pipes shall not be used as soil, waste, or vent
pipes, and soil, waste, or vent pipes shall not be used as conductors.

1104.2 Combining storm with sanitary drainage correct answers The sanitary and storm drainage
systems of a structure shall be entirely separate except where combined sewer systems are
utilized. Where a combined sewer is utilized, the building storm drain shall be connected to the
sanitary sewer exterior to the building.

1104.3 Floor Drains correct answers Floor drains shall not be connected to a storm drain

1105.1 Strainers correct answers Roof drains shall have strainers extended not less than 4 inches
(102mm) above the surface of the roof immediately adjacent to the roof drain. Strainers shall
have an available inlet area, above roof level, of not less than one and one-half times the area of
the conductor or leader to which the drain is connected

1105.2 Flat decks correct answers Roof drain strainers for use on sub decks, parking decks, and
similar areas that are normally serviced and maintained shall comply with Section 1105.1 or

Written for

Institution
Plumbing code
Course
Plumbing code

Document information

Uploaded on
March 15, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$10.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton NURSING, ECONOMICS, MATHEMATICS, BIOLOGY, AND HISTORY MATERIALS BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS, AND STUDY GUIDE MATERIALS WITH GUARANTEED A+ I am a dedicated medical practitioner with diverse knowledge in matters
Follow You need to be logged in order to follow users or courses
Sold
784
Member since
3 year
Number of followers
438
Documents
38837
Last sold
1 day ago
Reign Supreme Scholarly || Enlightened.

Get your revised study materials available here and elevate your educational outcomes. I have numerous verified learning materials (Research, Exams Questions and answers, Assignments, notes etc) for different courses guaranteed to boost your academic results. I am dedicated to offering you the best and unique learning content. You are encouraged to inquire further assistance from this end whenever need be. Kindly remember to leave your review, understanding your satisfaction is essential . We highly appreciate clients who always come back for more of the study content we offer, you are extremely valued. All the best.

Read more Read less
3.7

116 reviews

5
49
4
20
3
23
2
8
1
16

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions