Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

NATE ICE EXAM QUESTIONS CORRECTLY ANSWERED.

Rating
-
Sold
-
Pages
12
Grade
A+
Uploaded on
16-03-2025
Written in
2024/2025

NATE ICE EXAM QUESTIONS CORRECTLY ANSWERED. After a vacuum pump has been used, a continuous pressure rise in the system most likely indicates - CORRECT ANSWER existence of a leak after a vacuum has been pulled to 500 microns, a pressure rise in the system, followed by a leveling-off at 1500 microns, most likely indicates the - CORRECT ANSWER presence of a moisture on initial start up of an air conditioning system, the temperature drop measured across the evaporator coil exceeds manufacturer's specifications. this condition most likely indicates - CORRECT ANSWER lack of refrigerant charge the technician is on a spring maintenance check of an air conditioning system. they find the following - head pressure is higher than normal, suction pressure higher than normal, superheat 0 degrees, condenser is clean, outdoor fan operation is normal, subcooling is 25 degrees. which of the following is most likely the problem? - CORRECT ANSWER non-condensibles in the system in a compressor, the internal overload senses the winding temperature and - CORRECT ANSWER amperage in the compressor circuit the function of an external equalizer line for a thermostatic expansion valve is to - CORRECT ANSWER reference the pressure at the evaporator outlet in a fixed orifice air conditioning system, the presence of non-condensables in the system will cause - - CORRECT ANSWER high head and high suction pressures which one of the following could possibly cause a noisy reciprocating compressor? - CORRECT ANSWER broken internal springs two places where superheating occurs in a system are the - CORRECT ANSWER evaporating coil and the compressor if the fan switch on a thermostat sub-base is set to ON and the blower motor is cycling on and off, the most probable cause is - - CORRECT ANSWER motor overload when you are checking for windings of a single-phase compressor with an ohmmeter, the highest ohm reading would be - - CORRECT ANSWER start to run a compressor does not run, although the condenser fan is operating. reading the compressor windings, the measured resistance between r to a is 5 ohms, r to c is open and s to c is open. the problem is due to - - CORRECT ANSWER internal overload being open a compressor with tight bearings will cause the amperage to draw to - CORRECT ANSWER rise above normal which of the following can be caused by insufficient air flow? - CORRECT ANSWER increased compressor failure a correct statement about a hard start kit is that it - CORRECT ANSWER increases starting torque across an r-22 suction line drier, how much pressure drop indicates changing the drier? - CORRECT ANSWER 3 psig which one of the following can be caused by a restricted air filter? - CORRECT ANSWER high superheat which of the following would most likely occur if a crankcase heater fails? - CORRECT ANSWER the refrigerant may not be driven out of the oil a correct statement concerning a relay is that it - CORRECT ANSWER consists of one or more contacts actuated by a solenoid coil the control voltage in an air conditioning system comes directly from - - CORRECT ANSWER the secondary of a step down transformer in a residence, a slight positive indoor air pressure - - CORRECT ANSWER minimizes infiltration which of the following is an important factor when selecting a location for placement of a condensing unit? - CORRECT ANSWER should avoid standing groundwater and roof water runoff which of the following installation steps is necessary to maximize the efficiency of a condensing unit? - CORRECT ANSWER minimum clearances must be maintained around the condensing unit

Show more Read less
Institution
NATE
Course
NATE

Content preview

NATE ICE EXAM QUESTIONS
CORRECTLY ANSWERED.

After a vacuum pump has been used, a continuous pressure rise in the system most likely indicates -
CORRECT ANSWER existence of a leak



after a vacuum has been pulled to 500 microns, a pressure rise in the system, followed by a leveling-off
at 1500 microns, most likely indicates the - CORRECT ANSWER presence of a moisture



on initial start up of an air conditioning system, the temperature drop measured across the evaporator
coil exceeds manufacturer's specifications. this condition most likely indicates - CORRECT ANSWER lack
of refrigerant charge



the technician is on a spring maintenance check of an air conditioning system. they find the following -
head pressure is higher than normal, suction pressure higher than normal, superheat 0 degrees,
condenser is clean, outdoor fan operation is normal, subcooling is 25 degrees. which of the following is
most likely the problem? - CORRECT ANSWER non-condensibles in the system



in a compressor, the internal overload senses the winding temperature and - CORRECT ANSWER
amperage in the compressor circuit



the function of an external equalizer line for a thermostatic expansion valve is to - CORRECT ANSWER
reference the pressure at the evaporator outlet



in a fixed orifice air conditioning system, the presence of non-condensables in the system will cause - -
CORRECT ANSWER high head and high suction pressures



which one of the following could possibly cause a noisy reciprocating compressor? - CORRECT ANSWER
broken internal springs



two places where superheating occurs in a system are the - CORRECT ANSWER evaporating coil and the
compressor

, if the fan switch on a thermostat sub-base is set to ON and the blower motor is cycling on and off, the
most probable cause is - - CORRECT ANSWER motor overload



when you are checking for windings of a single-phase compressor with an ohmmeter, the highest ohm
reading would be - - CORRECT ANSWER start to run



a compressor does not run, although the condenser fan is operating. reading the compressor windings,
the measured resistance between r to a is 5 ohms, r to c is open and s to c is open. the problem is due to
- - CORRECT ANSWER internal overload being open



a compressor with tight bearings will cause the amperage to draw to - CORRECT ANSWER rise above
normal



which of the following can be caused by insufficient air flow? - CORRECT ANSWER increased compressor
failure



a correct statement about a hard start kit is that it - CORRECT ANSWER increases starting torque



across an r-22 suction line drier, how much pressure drop indicates changing the drier? - CORRECT
ANSWER 3 psig



which one of the following can be caused by a restricted air filter? - CORRECT ANSWER high superheat



which of the following would most likely occur if a crankcase heater fails? - CORRECT ANSWER the
refrigerant may not be driven out of the oil



a correct statement concerning a relay is that it - CORRECT ANSWER consists of one or more contacts
actuated by a solenoid coil



the control voltage in an air conditioning system comes directly from - - CORRECT ANSWER the
secondary of a step down transformer

Written for

Institution
NATE
Course
NATE

Document information

Uploaded on
March 16, 2025
Number of pages
12
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ROSEGRADES Nursing
Follow You need to be logged in order to follow users or courses
Sold
227
Member since
3 year
Number of followers
87
Documents
12151
Last sold
1 week ago
TOPGRADE

I HELP STUDENTS WITH REVISION MATERIALS WITH BETTER GRADES GUARANTEED. BEST OF LUCK.

3.4

35 reviews

5
12
4
4
3
11
2
3
1
5

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions