CNOR EXAM//CNOR PRACTICE EXAM// CNOR EXAM STUDY G
l l l l l l l
UIDE TESTBANK NEWEST VERSION QUESTIONS ACTUAL EXA
l l l l l l
M 500+ QUESTIONS AND CORRECT DETAILED ANSWERS(VERI
l l l l l l l
FIED ANSWERS) |ALREADY GRADED A+ l l l l
What are types of automatic cleaning (2)? How effective is it? -
l l l l l l l l l l l
CORRECT ANSWER >>>>washer and ultrasonic, more effective thanm
l l l l l l l l l
anual cleaning l
Pre-vacuum autoclave (Dynamic air removal)- l l l l
type, temp, porous/lumen vs non porous time -
l l l l l l l l
CORRECT ANSWER >>>>-steamsterilization
l l l l
-
sucks air out of chamber and the steam comes in cleaning theinstrume
l l l l l l l l l l l l
nts
-clean drains are essential
l l l
-270-276 degrees F l l
-porous/lumen items in for 4 mins l l l l l
-nonporous items in for 3 mins l l l l l
,2 |lPl al gl e
Gravity displacement autoclave- l l
type, temp, porous/lumen, nonporous items -
l l l l l l
CORRECT ANSWER >>>>steam forces air fromchamber
l l l l l l l
thermometer closes drain l l l
270-276 degrees F l l
porous/lumen items in for 10 minsn l l l l l l
onporous items in for 3 mins always f l l l l l l l
ollow IFUs l
How do you avoid condensation when sterilizing items? what should y
l l l l l l l l l l
ou allow between trays? when should you remove the trays? where sh
l l l l l l l l l l l
ould you place the trays after sterilizing? what doesit mean when the tr
l l l l l l l l l l l l l
ay is moist? what should you not do to cool down the instruments? -
l l l l l l l l l l l l l
CORRECT ANSWER >>>>Allow airflow between trays
l l l l l l
remove loads immediately (leaving door ajar to cool increaseslik
l l l l l l l l l
elihood of condensation) l l
Don't put hot items on a cool solid surface or rack
l l l l l l l l l l
If condensation occurs and the items are moist, they arecon
l l l l l l l l l l
sidered unsterile l
What are the 6 chemical indicators? 1,2 and 5 are most important.what
l l l l l l l l l l l l l
are the 4 parameters of sterilization? - CORRECT ANSWER
l l l l l l l l
>>>>1. temp/heat, the tray go hot enough, external factor.
l l l l l l l l
2. pressure/bowie dick- l
tests all air was removed and enoughpressure was present only p
l l l l l l l l l l l l
revac, only tells vacuum was used l l l l l
3. single parameter (based on manufacturer) quality l l l l l
4. multi-parameter (based on manufacturer) (ex quality and time) l l l l l l l
5. integrated (all parameters like time, temp, pressure and qualityof l l l l l l l l l l
steam)
,3 |lPl al gl e
6. emulating indicator (all parameters of a particular style likema l l l l l l l l l
nufacturer for specific autoclave for a specific cycle l l l l l l l
Chemical indicators only indicate whether that specific cycle wasme l l l l l l l l l
t. Does not determine sterilization
l l l l
What indicator are external indicators? - CORRECT ANSWER >>>>1
l l l l l l l l
- heat
l
What indicator are Bowie dick tests? - CORRECT ANSWER >>>>2 -
l l l l l l l l l l
pressure (used with pre-vac)
l l l l
IUSS-
how can the item be wrapped? what kind of indicator must be used? w
l l l l l l l l l l l l l l
hat item cannot be used unless its an emergency? whatprocess must sti
l l l l l l l l l l l l
ll occur when using IUSS? what must you keep for patient safety? wrap
l l l l l l l l l l l l
ped vs unwrapped goods length of tie and temperature? -
l l l l l l l l l
CORRECT ANSWER >>>>no packaging, wrapped items or textiles due t
l l l l l l l l l l
o an abbreviated dry time
l l l l
same decon process l l
rigid sterilization containers with lid m
l l l l l
ust use a class 5 chemical indicatornev
l l l l l l l
er an implant unless emergent
l l l l
sterilization log must be kept for patient safety l l l l l l l
Unwrapped goods: 3-5 minutes at 270-275°F (132- l l l l l l
135°C)Wrapped goods: 6-10 minutes at 270-275°F l l l l l l
What happens if the IUSS fails a quality check? - CORRECT ANSWER
l l l l l l l l l l l
>>>>If a QC fails, run 3 consecutive a spore tests l l l l l l l l l
If one fails again, biomed checks IUSS and has to pass 3 consecutivetests
l l l l l l l l l l l l l
to use it again
l l l l
, 4 |lPl al gl e
Gluteraldehyde-
What kind of sterilization? where is this used? howlong does it take? is it
l l l l l l l l l l l l l l l l
often used, why? - CORRECT ANSWER l l l l l
>>>>cold sterilization l l
POC use only l l
Takes 10 hours of immersion l l l l
Bad for instruments due to pitting
l l l l l
Suboptimal form of sterilization due to environmental problemsan l l l l l l l l
d poor ease of use
l l l l
Ethylene oxide- l
what can it be used on? how long does it take? how long is aeration time
l l l l l l l l l l l l l l l l
? is it often used, why? what temperatureand humidity does EO need to
l l l l l l l l l l l l l
be*? - CORRECT ANSWER >>>>cold and dry form of sterilization
l l l l l l l l l l
for heat + moisture sensitive items (99-145 degree F and 45-
l l l l l l l l l l
75%humidity) l
2-5 hours exposure
l l
8-12 hour aeration time l l l
Human carcinogen (exposure limited to 1PPM in an 8 hr period)Luml l l l l l l l l l l
ens must be completely dry (great for foleys) Environmentally hazar
l l l l l l l l l
dous
Will make antifreeze with waterb
l l l l l
accilus atropheus l
Low Temp Hydrogen Peroxide Plasma Sterilization (aka Sterrad orVP
l l l l l l l l l
RO)-
What is it good for? How long does it take? How long is aeration? How
l l l l l l l l l l l l l l l l
does it work? - CORRECT ANSWER >>>>-
l l l l l l
Use for heat + moisture sensitive items
l l l l l l l
- No aeration cycle needed - dry sterilization
l l l l l l
- Cycle time 75 mins l l l
- Environmentally sound l