WITH ACCURATE SOLUTIONS
Plumbing Code Regulation SBC-3 - ✅✅✅CORRECT -State of Rhode Island Plumbing Code is
known as:
4' 6" Below Grade - ✅✅✅CORRECT -Water Services Shall Be Installed Not Less Than:
Insulated/Heated or Both - ✅✅✅CORRECT -Piping installed in exterior walls or areas
subject to freezing must:
36" Below Grade - ✅✅✅CORRECT -Building Sewers connected to a public sewer shall have
a minimum coverage of:
Under a water heater 6 gallons or greater that is elevated - ✅✅✅CORRECT -A safe waste
pan shall be installed
2" deep with 2" clearance around heater - ✅✅✅CORRECT -A safe waste pan shall be at
least
10' undisturbed compacted earth - ✅✅✅CORRECT -Water service piping and building
drain/sewer shall be separated by:
Water line is installed minimum 12" above sewer line at highest point - ✅✅✅CORRECT -
Water service separation distance is not required if:
50' - ✅✅✅CORRECT -Distance for a septic tank/sewer to a private water supply(well) is:
, 6"below the roof with an approved fitting - ✅✅✅CORRECT -Where frost closure is common
an increase in vent size shall take place:
"V" zone (subject to wave heights in excess of 3') - ✅✅✅CORRECT -High Hazard flood zone
is:
8.0% Lead - ✅✅✅CORRECT -Lead free pipe and fittings contain less than:
110 degrees - ✅✅✅CORRECT -Hot water is water at temperature greater than or equal to:
0.2% Lead - ✅✅✅CORRECT -Lead free solder and flux contain no more than
0.5 inches - ✅✅✅CORRECT -Strainer plates on drain lines for rodent proofing must have
openings:
Two pipe size greater than the pipe passing through it - ✅✅✅CORRECT -Sleeves for pipes
passing through foundation walls or under footings shall be:
500' - ✅✅✅CORRECT -Travel distance to toilet facilities in merchantile/occupancies are:
300' - ✅✅✅CORRECT -Travel distance to toilet facilities in covered malls are:
15" - ✅✅✅CORRECT -Water closets, bidets or lavatories shall have a clearance from center
of fixture to wall of:
21" - ✅✅✅CORRECT -The required clearance from front of fixture to a wall, door or other
fixture is: