Questions with 100% Verified Correct Answers
Guaranteed A+
(true or false) Fastener components that accumulate rust or dirt may be incorporated
into the work if they are requalified. - CORRECT ANSWER: True - Section 2.2 -
Specification for Structural Joints
A representative sample of not fewer than "BLANK" fasteners assemblies of each
combination of diameter, length, and grade of bolt used in the work shall be checked at
the site of installation to verify that the pretensioning method develops a pretension that
is equal to or greater "BLANK" times than specified. - CORRECT ANSWER: three and
1.05
A tension calibrator shall be used where bolts are to be installed in: - CORRECT
ANSWER: Pretensioned joints
According to the AISC Steel Construction Manual, the grout used between the column
base plate and the foundation must be: - CORRECT ANSWER: High-strength non-
shrink
According to the AISC Steel Construction Manual, the minimum washer thickness for a
base plate anchor rod 1 inch diameter is "BLANK" inches. - CORRECT ANSWER: ⅜
inch - Table 14-2, Part 14, AISC Steel Construction Manual
According to the AISC Steel Construction Manual, the recommended maximum size of
anchor rod hole in a base plate for a 1 inch diameter anchor rod is "BLANK" inches. -
CORRECT ANSWER: 1-13/16 inches - Table 14-2, Part 14, AISC Steel Construction
Manual
,According to the AISC Steel Construction Manual, what should be done if grouting is
delayed on a base plate supported by leveling nuts until after steel erection? -
CORRECT ANSWER: Use steel shims to support the base plate. Page 14-7, Part 14,
AISC Steel Construction Manual
According to the AISC Steel Construction Manual, which of the following is not an
allowed manner for setting column base plates? - CORRECT ANSWER: treated-
hardwood shims
According to the Code of Standard Practice "BLANK" of the steel surface is required
prior to shop painting. - CORRECT ANSWER: Wire Brushing - Section 6.5.2 - Code of
Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, "BLANK"
are allowed in moderate amounts for correction of errors during steel framing erection. -
CORRECT ANSWER: drift pins, grinding, and reaming. - Section 7.14 - Code of
Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, "BLANK" is
the tolerance on the length of a floor beam that is less than 30 feet long. - CORRECT
ANSWER: 1/16 inch - Section 6.4.1 - Code of Standard Practice for Steel Buildings and
Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, how are
fabricators stock steel material identified? - CORRECT ANSWER: Certified mill test
reports - Section 5.2.2 - Code of Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, how is steel
of special material to be identified? - CORRECT ANSWER: It is marked by the supplier -
Section 5.1.1, Code of Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, the
"BLANK" is responsible for the temporary vertical and lateral supports necessary for the
, erection of the building framework. - CORRECT ANSWER: Steel erection contractor -
Section 7.10.3 - Code of Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, the
"BLANK" must be approved before the fabrication of the structural steel begins. -
CORRECT ANSWER: shop and erection drawings - Section 4.4.1 - Code of Standard
Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, the number
of samples required to be tested for structural steel is: - CORRECT ANSWER: The
number specified by the ASTM specification - Section 5.1.1 - Code of Standard Practice
for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, the
permitted method of applying shop paint is: - CORRECT ANSWER: Brushing, Rolling,
or spraying - Section 6.5.3 - Code of Standard Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, what party
is to review the fabricators shop and erection drawings? - CORRECT ANSWER:
Owner's representatives for design and construction - Section 4.4 -Code of Standard
Practice for Steel Buildings and Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, what types
of openings for other trades are allowed to be cut in the structural steel? - CORRECT
ANSWER: Only those openings shown on the contract document drawings and
specifications. - Section 7.15 - Code of Standard Practice for Steel Buildings and
Bridges
According to the Code of Standard Practice for Steel Buildings and Bridges, which party
performs material tests of the structural steel for verification of material properties? -
CORRECT ANSWER: Steel supplier