1. Technician A says that evacuating an A/C system will remove air and moisture
from the system. Technician B says that evacuating an A/C system will remove dirt
particles from the system. Who is right?
A. Technician A only
B. Technician B only
C. Both A and B
D. Neither A or B - ANSWER-A


2. There is a growling or rumbling noise at the A/C compressor when the system is
off and the engine is running. The noise stops when the system is turned on.
Technician A says that a bad compressor bearing could be the cause. Technician B
says that a bad compressor clutch bearing could be the cause. Who is right?
A. Technician A only
B. Technician B only
C. Both A and B
D. Neither A or B - ANSWER-b


3. The readings shown above are taken with the A/C system operating at an
ambient (outside) temperature of 85°F (29°C). What do the readings indicate?
A. normal operation
B. low refrigerant level

,C. a restriction in the high side
D. damaged compressor - ANSWER-b


4. Recovery/recycling equipment must have shutoff valves located within 12-in.
(30 cm) of the hoses' service ends so that:
A. oil can be added to the refrigerant
B. the unit can be isolated from the refrigerantsource
C. the filter can be changed without disconnecting the hoses
D. refrigerant discharge can be kept to a minimum - ANSWER-d


5. When recovering refrigerant from an A/C system, how long should the
technician wait after the recovery/ recycling unit has been turned off to see if
there is any residual pressure in the system?
A. 1 minute
B. 5 minutes
C. 10 minutes
D. 15 minutes - ANSWER-b


6. A system with a low pressure on the low side anda heavy frost accumulation on
the inlet side of the Thermostatic Expansion Valve (TXV) indicates a:
A. TXV stuck open
B. clogged condenser
C. defective compressor
D. clogged screen or TXV stuck closed - ANSWER-d

, 7. A blower motor only works on high speed. Which ofthe following causes is the
MOST LIKELY?
A. defective blower relay
B. defective blower resistor
C. defective blower switch
D. blown fuse or tripped circuit breaker - ANSWER-b


8. A customer complains that when accelerating his car with the A/C on, the cold
air flow from the dash outlets shifts to the floor. Technician A says that this is
caused by a faulty check valve in the vacuum reservoir. Technician B says that this
condition is due to a vacuum leak. Who is right?
A. Technician A only
B. Technician B only
C. Both A and B
D. Neither A or B - ANSWER-c


9. When pressure testing the cooling system on a late model gasoline engine
vehicle, the pressure on the tester drops but no leaks can be found in the engine
compartment. Technician A starts the engine and, seeing the pressure on the
tester gauge increase, says that there is an internal leak, a blown head gasket.
Technician B says that there cannot be an internal leak because the engine oil
looks normal, not milky like it would be if coolant were present, and there is no
white smoke coming from the exhaust pipe. Who is right?
A. Technician A only
B. Technician B only
C. Both A and B
D. Neither A or B - ANSWER-a

Geschreven voor

Instelling
ASE AC 609
Vak
ASE AC 609

Documentinformatie

Geüpload op
26 maart 2025
Aantal pagina's
24
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$20.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NurseSue Johns Hopkins University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
56
Lid sinds
2 jaar
Aantal volgers
4
Documenten
1170
Laatst verkocht
1 week geleden

3.8

9 beoordelingen

5
4
4
1
3
3
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen