Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

EEG BOARD PREP 2025 EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED

Rating
-
Sold
-
Pages
10
Grade
A+
Uploaded on
28-03-2025
Written in
2024/2025

EEG BOARD PREP 2025 EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED Practice questions for this set Terms in this set (169) The EEG amplifier is designed so that when input 1 is more negative than input 2, the deflection will be UPWARD Common Mode Rejection the characteristic of an amplifier that rejects external interference WHICH OF THE FOLLOWING IS MOST ATTENUATED BY A LOW FREQUENCY FILTER OF 1HZ 0.1 HZ TIME CONSTANT IS DEFINED AS THE TIME REQUIRED TO... FOR THE DEFLECTION TO FALL (DECAY) TO 67% OF THE PEAK DEFLECTION An EEG record has 3/sec spike & wave discharges. Both the spike and the slow wave have voltages of 100uV. If this discharge is recorded with a LFF of 5Hz and a sensitivity of 10uV/mm, what would be the deflection of the spike and the wave? a. spike 10mm & wave 6mm b. spike 6mm & wave 10mm c. spike 10mm & wave 10mm d. spike 6mm & wave 6mm SPIKE 10MM, WAVE 6MM A HIGH FREQUENCY SETTING OF 35HZ WOULD ATTENUATE 50HZ MUSCLE ACTIVITY BY APPROXIMATELY WHAT PERCENTAGE? 40% ACCORDING TO ACNS GUIDELINES, RECORDING CLINICAL EEG ON DIGITAL MEDIA REQUIRES MONITORS TO HAVE WHAT BETWEEN 25 AND 35MM/SECOND HORIZONTAL SCALING AND A MINIMUM OF 100 DATA POINTS/SECOND TO ACCURATELY DISPLAY EEG ON THE MONITOR SCREEN IN A RECORD WITH 10HZ ALPHA ACTIVITY. WHEN THE DISPLAY EPOCH IS CHANGED FROM 10 SECONDS PER DISPLAY SCREEN TO 20 SECONDS PER DISPLAY SCREEN, THE FREQUENCY OF THE ACITIVTY WILL BE WHAT? 10HZ GUIDELINES FOR RECORDING DIGITAL EEG ARE WRITTEN BY WHO? THE AMERICAN CLINICAL NEUROPHYSIOLOGY SOCIETY (ACNS) THE TERM RAM MEANS WHAT TEMPORARY MEMORY STORAGE THAT IS CRITICAL TO RAPID COMPUTER OPERATIONS THE ELECTRODE SITE THAT IS LOCATED 1CM ABOVE, ONE THIRD THE DISTANCE OUT FROM THE LEFT EXTERNAL AUDITORY MEATUS TOWARDS THE LEFT OUTER CANTHUS IS CALLED WHAT T1 OR F9 Due to a central scalp lesion, C4 has to be relocated 4mm anteriorly. The technologist should: a. relocate C3 4mm anteriorly b. make no other placement changes c. relocate P3 4mm anteriorly d. relocate all electrodes in the right parasagittal plane 4mm anteriorly A. RELOCATE C3 4MM ANTERIORLY IN A REFERENTIAL MONTAGE, HOW IS THE ORIGIN OF THE POTENTIAL DETERMINED? AMPLITUDE WHEN RECORDING FOR ECI, INTERELECTRODE IMPEDANCES SHOULD BE AT LEAST OHMS, BUT LESS THAN _ OHMS. 100----10,000 WHEN RECORDING FOR ECI, IT IS RECOMMENDED THAT THE SENSITIVITY BE uV/MM AND THE LOW FILTER SHOULD NOT BE HIGHER THAN HZ. FOR AT LEAST MINS OF RECORDING. 2uV, 1.0HZ, 30 MINS THE TRACTS CONNECTING THE RIGHT AND LEFT HEMISPHERES ARE CALLED WHAT? CORPUS CALLOSUM THE CENTRAL SULCUS (FISSURE OF ROLANDO) DEMARCATES WHAT? FRONTAL AND PARIETAL LOBES THE TRIGEMINAL NERVE DOES? IS THE MAJOR SENSORY NERVE OF THE FACE

Show more Read less
Institution
Course

Content preview

3/25/25, 7:48
AM

EEG BOARD PREP 2025 EXAM QUESTIONS AND ANSWERS WITH
COMPLETE SOLUTIONS VERIFIED
Practice questions for this set


Learn 1/7 Study using Learn




MEDULLA



Select the correct term



THE CARDIOVASCULAR AND RESP
The EEG amplifier is designed so that when
CENTERS FOR AUTOMATIC CONTROL OF
1input 1 is more negative than input 2, the
2HEART RATE AND RESPIRATION ARE FOUND IN?
deflection will be




THE TRACTS CONNECTING THE RIGHT
3AND LEFT HEMISPHERES ARE CALLED WHAT? 4REM SLEEP CHARACTERIZED BY?




Don't know?




Terms in this set (169)

The EEG amplifier is designed so that when UPWARD
input 1 is more negative than input 2, the
deflection will be

Common Mode Rejection the characteristic of an amplifier that rejects external interference

WHICH OF THE FOLLOWING IS MOST 0.1 HZ
ATTENUATED BY A LOW FREQUENCY
FILTER OF 1HZ

TIME CONSTANT IS DEFINED AS THE TIME FOR THE DEFLECTION TO FALL (DECAY) TO 67% OF THE PEAK DEFLECTION
REQUIRED TO...

An EEG record has 3/sec spike & SPIKE 10MM, WAVE 6MM
wave discharges. Both the spike and
the slow wave have voltages of
100uV. If this
discharge is recorded with a LFF of
5Hz and a sensitivity of 10uV/mm, what
would be the deflection of the spike
and the wave?
a.spike 10mm & wave 6mm
b. spike 6mm & wave 10mm
c. spike 10mm & wave 10mm
d. spike 6mm & wave 6mm

1/10

, 3/25/25, 7:48
AM
A HIGH FREQUENCY SETTING OF 35HZ 40%
WOULD ATTENUATE 50HZ MUSCLE
ACTIVITY BY APPROXIMATELY WHAT
PERCENTAGE?

ACCORDING TO ACNS GUIDELINES, BETWEEN 25 AND 35MM/SECOND HORIZONTAL SCALING AND A MINIMUM OF
RECORDING CLINICAL EEG ON DIGITAL 100 DATA POINTS/SECOND TO ACCURATELY DISPLAY EEG ON THE MONITOR
MEDIA REQUIRES MONITORS TO HAVE SCREEN
WHAT

IN A RECORD WITH 10HZ ALPHA 10HZ
ACTIVITY. WHEN THE DISPLAY EPOCH IS
CHANGED FROM 10 SECONDS PER
DISPLAY SCREEN TO 20 SECONDS PER
DISPLAY SCREEN, THE FREQUENCY OF
THE ACITIVTY WILL BE WHAT?

GUIDELINES FOR RECORDING DIGITAL THE AMERICAN CLINICAL NEUROPHYSIOLOGY SOCIETY (ACNS)
EEG ARE WRITTEN BY WHO?

TEMPORARY MEMORY STORAGE THAT IS CRITICAL TO RAPID COMPUTER
THE TERM RAM MEANS WHAT
OPERATIONS

THE ELECTRODE SITE THAT IS LOCATED T1 OR F9
1CM ABOVE, ONE THIRD THE DISTANCE
OUT FROM THE LEFT EXTERNAL
AUDITORY MEATUS TOWARDS THE LEFT
OUTER CANTHUS IS CALLED WHAT




2/10

Written for

Course

Document information

Uploaded on
March 28, 2025
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$10.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AcademicSuperScores Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
299
Member since
3 year
Number of followers
37
Documents
7648
Last sold
1 week ago
AcademicSuperScores

NURSING, ECONOMICS, MATHEMATICS, BIOLOGY AND HISTORY MATERIALS. BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS AND STUDY GUIDE MATERIALS WITH GUARANTEE OF A+ I am a dedicated medical practitioner with diverse knowledge in matters Nursing and Mathematics. I also have an additional knowledge in Mathematics based courses (finance and economics)

4.6

156 reviews

5
125
4
9
3
11
2
5
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions