Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

National Certification Corporation (NCC) Electronic Fetal Monitoring Certification Exam Questions & Answers, Rated 100%

Beoordeling
-
Verkocht
-
Pagina's
72
Cijfer
A+
Geüpload op
31-03-2025
Geschreven in
2024/2025

National Certification Corporation (NCC) Electronic Fetal Monitoring Certification Exam Questions & Answers, Rated 100%-Which of the following factors can have a negative effect on uterine blood flow? a. Hypertension b. Epidural c. Hemorrhage d. Diabetes e. All of the above - e. All of the above How does the fetus compensate for decreased maternal circulating volume? a. Increases cardiac output by increasing stroke volume. b. Increases cardiac output by increasing it's heart rate. c. Increases cardiac output by increasing fetal movement. - b. Increases cardiac output by increasing it's heart rate. Stimulating the vagus nerve typically produces: a. A decrease in the heart rate b. An increase in the heart rate c. An increase in stroke volume d. No change - a. A decrease in the heart rate What initially causes a chemoreceptor response? a. Epidurals b. Supine maternal position c. Increased CO2 levels d. Decreased O2 levels e. A & C f. A & B g. C & D - g. C & D The vagus nerve begins maturation 26 to 28 weeks. Its dominance results in what effect to the FHR baseline? a. Increases baseline b. Decreases baseline - b. Decreases baseline T/F: Oxygen exchange in the placenta takes place in the intervillous space. - True T/F: The parasympathetic nervous system is a cardioaccelerator. - False T/F: Baroreceptors are stretch receptors which respond to increases or decreases in blood pressure. - True T/F: There are two electronic fetal monitoring methods of obtaining the fetal heart rate: the ultrasound transducer and the fetal spiral electrode. - True T/F: Variability can be determined with the fetoscope. - False T/F: Because the ultrasound transducer and toco transducer are sealed units, they can be dipped in warm water to make cleaning easier. - False T/F: The most common artifact with the ultrasound transducer system for fetal heart rate is increased variability. - True T/F: All fetal monitors contain a logic system designed to reject artifact. - True T/F: The monitor should always be tested before starting a tracing, either external or internal mode and labeled a test. - True T/F: The paper speed on the fetal monitor should always be set at 1cm/min. - False T/F: Both internal and external monitoring methods are equally accurate means of obtaining the fetal heart rate and contraction patterns. - False T/F: The external toco is usually placed over the uterine fundus to pick up contractions. - True T/F: The external toco gives measurable uterine pressure. - False T/F: The fetal spiral electrode can be placed when vaginal bleeding of unknown origin is present. - False T/F: The ultrasound transducer is usually placed on the side of the uterus over the baby's back, as the fetal heart is heard best there. - True T/F: The spiral electrode is used to more accurately determine the frequency, duration, and intensity of uterine contractions. - False T/F: The heart rate from a well-applied fetal spiral electrode can only be fetal, not maternal. - False

Meer zien Lees minder
Instelling
NCC EFM Certification
Vak
NCC EFM Certification











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
NCC EFM Certification
Vak
NCC EFM Certification

Documentinformatie

Geüpload op
31 maart 2025
Aantal pagina's
72
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$14.24
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ProfMiaKennedy Arizona State University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2009
Lid sinds
5 jaar
Aantal volgers
1610
Documenten
3258
Laatst verkocht
2 dagen geleden

We all get stuck sometimes, you feel frustrated about exams coming up and not fully prepared? Worry no more mate, with my documents i assure you atleast an A, get unstuck with the most recent, analyzed and graded exams with just a simple mouse click... Download and crash those exams!!

3.9

384 beoordelingen

5
198
4
58
3
56
2
25
1
47

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen