Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

WRITTEN EXAM REVIEW PRACTICE TEST 1 AND 2 WITH CORRECT QUESTIONS AND ANSWERS.

Beoordeling
-
Verkocht
-
Pagina's
9
Cijfer
A
Geüpload op
03-04-2025
Geschreven in
2024/2025

assuming all other conditions remain constant, a decrease in evaporator load causes - CORRECT ANSWERS.️️low suction pressure in a flooded evaporator using an accumulator and float valve, flash gas - CORRECT ANSWERS.️️passes directly into the suction line the oil trap on a refrigeration system is on the - CORRECT ANSWERS.️️discharge line, as close to the compressor as allowed what controls the operation of a high-side float? - CORRECT ANSWERS.️️the condenser, and receiver when suction pressure decreases,compressor capacity - CORRECT ANSWERS.️️decreases cooling-tower water should be maintained at a p h near - CORRECT ANSWERS.️️7.8 the sub cooling effect of the liquid refrigerant just before the expansion valve causes increased - CORRECT ANSWERS.️️refrigeration effect sub cooling the liquid refrigerant just before the expansion valve, results in an increase in - CORRECT ANSWERS.️️refrigeration effect what percent of oil travels with the refrigerant? - CORRECT ANSWERS.️️10 percent any water present in the refrigerant side of a freon refrigeration system causes a - CORRECT ANSWERS.️️frozen expansion valve when heated, R-12 changes to - CORRECT ANSWERS.️️phosgene gas in an absorption system, the medium normally used to vaporize refrigerant and increase its temperature is - CORRECT ANSWERS.️️steam

Meer zien Lees minder
Instelling
Ammonia Refigdweration
Vak
Ammonia refigdweration

Voorbeeld van de inhoud

WRITTEN EXAM REVIEW PRACTICE
TEST 1 AND 2 WITH CORRECT
QUESTIONS AND ANSWERS.

assuming all other conditions remain constant, a decrease in evaporator load causes - CORRECT
ANSWERS.✔️✔️low suction pressure



in a flooded evaporator using an accumulator and float valve, flash gas - CORRECT
ANSWERS.✔️✔️passes directly into the suction line



the oil trap on a refrigeration system is on the - CORRECT ANSWERS.✔️✔️discharge line, as close to the
compressor as allowed



what controls the operation of a high-side float? - CORRECT ANSWERS.✔️✔️the condenser, and
receiver



when suction pressure decreases,compressor capacity - CORRECT ANSWERS.✔️✔️decreases



cooling-tower water should be maintained at a p h near - CORRECT ANSWERS.✔️✔️7.8



the sub cooling effect of the liquid refrigerant just before the expansion valve causes increased -
CORRECT ANSWERS.✔️✔️refrigeration effect



sub cooling the liquid refrigerant just before the expansion valve, results in an increase in - CORRECT
ANSWERS.✔️✔️refrigeration effect



what percent of oil travels with the refrigerant? - CORRECT ANSWERS.✔️✔️10 percent



any water present in the refrigerant side of a freon refrigeration system causes a - CORRECT
ANSWERS.✔️✔️frozen expansion valve

, when heated, R-12 changes to - CORRECT ANSWERS.✔️✔️phosgene gas



in an absorption system, the medium normally used to vaporize refrigerant and increase its temperature
is - CORRECT ANSWERS.✔️✔️steam



which does not increase the capacity of a water-cooled condenser? - CORRECT
ANSWERS.✔️✔️decreasing the ambient temperature



when energizing a solenoid valve, to close the valve, its position would normally be - CORRECT
ANSWERS.✔️✔️normally open



a valve that does not restrict flow is the - CORRECT ANSWERS.✔️✔️solenoid valve



the oil separator is located on the - CORRECT ANSWERS.✔️✔️discharge line, as far from the compressor
as possible



when we say a refrigerant is anhydrous, we mean - CORRECT ANSWERS.✔️✔️water is absent



the primary purpose of a purger, in a freon system is the removal of - CORRECT
ANSWERS.✔️✔️noncondensables



operating a freon air-conditioning unit with the filters clogged, is likely to result in - CORRECT
ANSWERS.✔️✔️low suction pressure



a refrigerant overcharge would - CORRECT ANSWERS.✔️✔️increase head pressure



on the most common three-phase, four-wire service, the voltage between any phase and neutral should
be - CORRECT ANSWERS.✔️✔️120 volts



the following statement about brine is true - CORRECT ANSWERS.✔️✔️p h should be slightly alkaline at
7.8

Geschreven voor

Instelling
Ammonia refigdweration
Vak
Ammonia refigdweration

Documentinformatie

Geüpload op
3 april 2025
Aantal pagina's
9
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$16.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
Sinzorah

Maak kennis met de verkoper

Seller avatar
Sinzorah Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
2 jaar
Aantal volgers
0
Documenten
318
Laatst verkocht
6 maanden geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen