The minimum distance for mounting of a spot type smoke detector from an air supply diffuser is? - 3' from diffusers This is regarding manual fire alarm boxes, NFPA 72 requires that they be conspicuous, unobstructed, and ________ - accessible Regarding manual fire alarm boxes, NFPA 72 requires that travel distance to the nearest fire alarm Box shall not exceed - 100 feet The maximum number of water flow switches permitted to be connected to a single IDC shall not exceed - 5 Fire pumps shall be supervised for: (find the incorrect answer) - Pump running - supervisory signal to meet the requirements for distinctive signals, building evacuation signals shall be? - ANSI 53.41 Temporal 3 signal

Meer zien Lees minder
Instelling
FSDNY
Vak
FSDNY

Voorbeeld van de inhoud

FSDNY S98 EXAM SCRIPT 2025/2026 QUESTIONS WITH
ANSWERS GRADED A+
✔✔The minimum distance for mounting of a spot type smoke detector from an air
supply diffuser is? - ✔✔3' from diffusers

✔✔This is regarding manual fire alarm boxes, NFPA 72 requires that they be
conspicuous, unobstructed, and ________ - ✔✔accessible

✔✔Regarding manual fire alarm boxes, NFPA 72 requires that travel distance to the
nearest fire alarm Box shall not exceed - ✔✔100 feet

✔✔The maximum number of water flow switches permitted to be connected to a single
IDC shall not exceed - ✔✔5

✔✔Fire pumps shall be supervised for: (find the incorrect answer) - ✔✔Pump running -
supervisory signal

✔✔to meet the requirements for distinctive signals, building evacuation signals shall
be? - ✔✔ANSI 53.41 Temporal 3 signal

✔✔A listed relay used to initiate fire safety functions shall be located within ________
_______ of the controlled circuit or appliance - ✔✔3 feet

✔✔Regarding elevator recall for fire fighters service, unless otherwise required by the
AHJ, only the _______ _________ smoke detectors shall be used to recall elevators for
fire fighters service name the 3 locations - ✔✔a) Elevator lobby
b) Elevator Hoist way
c) Elevator machine Room

✔✔Where he detectors are used to shut down elevator power prior to sprinkler
operation, the heat detector shall have both a ________ ________ ___________ and a
__________ _____________ as compared to the sprinkler - ✔✔A lower temperature
rating and a higher sensitivity

✔✔Where heat detectors are used to shut down elevator power prior to sprinkle
operation, the detector shall be placed within _________ for each sprinkler head - ✔✔2
feet

✔✔What is the maximum candella (cd) reading for a visible appliance? - ✔✔1000 CD

, ✔✔For visibles signaling appliances, the Flash rate shall not exceed ________ or be
less then _________ throughout the listed voltage range of the client - ✔✔2hz - 1hz per
second

✔✔What are the name plate requirements for audible appliances? - ✔✔Autubel devices
shall be stamped with that sound pressure level And autubel devices shall be stamped
with their electrical requirements

✔✔Public mode audible devices shall have a sound level at least _______ above The
average ambient sound level or _______ above the maximum sound level having a
duration of at least 60 seconds, which ever is greater. - ✔✔15db - 5db

✔✔Wall mount to the visible appliances shall be mounted so that the entire lens is not
less than ________ nor greater than __________ above the finished floor - ✔✔80
inches to 96 inches above floor

✔✔Multiple visible appliances in the same field of view must be - ✔✔synchronized

✔✔Visible signaling appliances installed in corridors less than 20' why shall be installed
within _____ of the end of the corridor. With a separation of no more than _______
between appliances. Fill in the blanks - ✔✔15' - 100'

✔✔You are assigned to install a visible appliance in a Room 20'×20'. What candela
reading would you use and how many appliances would you need? - ✔✔15 cd - 1

✔✔Upon receipt of an alarm signal initiated by automatic fire detectors, water flow, or
actuation of other fire suppression systems the control station shall: (choose the
incorrect answer) - ✔✔Call the premise to verify the alarm, Then re transmit the signal
to the public fire service

✔✔Upon receipt of a trouble signal or other signal referring to matters of equipment
maintenance, the central station shall dispatch personnel to arrive at the premises
within _____ hours to initiate maintenance if necessary - ✔✔4 hours

✔✔Regarding a supervising station, complete records of all singles received sell be
retained for at least _________ - ✔✔1 year

✔✔Remote supervising stations are required to be manned at all times, how many
trained and competent persons are required to be on duty at all times? - ✔✔no less
than 2

Geschreven voor

Instelling
FSDNY
Vak
FSDNY

Documentinformatie

Geüpload op
4 april 2025
Aantal pagina's
6
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
EXAMCAFE Chamberlain College Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
133
Lid sinds
1 jaar
Aantal volgers
3
Documenten
17190
Laatst verkocht
4 dagen geleden
EXAM CAFE

Welcome to Exam Docs Hub, the ultimate online destination for high-quality exam documents, study guides, and academic resources to help you excel in your studies! Whether you're preparing for final exams, standardized tests, certifications, or coursework, we provide comprehensive and well-structured materials to boost your confidence and performance. Our collection includes: ✅ Past exam papers for various subjects ✅ Study guides & summaries to simplify learning ✅ Practice tests & quizzes to assess your knowledge ✅ Detailed solutions & answer keys for effective revision At Exam Docs Hub, we prioritize accuracy, quality, and accessibility. Our resources are carefully curated to meet the needs of students, educators, and professionals. With instant downloads and user-friendly access,

Lees meer Lees minder
3.2

17 beoordelingen

5
6
4
3
3
2
2
1
1
5

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen