Journeyman and Master Plumbing Exam Question and Answers Fully Solved What degree is used for isometric drawings? - Answers 60 degrees What is the recommended minimum of minutes for chlorine water management? - Answers 20-30 minutes When you need to repair a single handle lavatory faucet, what needs to be replaced? - Answers O ring Galvanic corrosion of water supply piping can occur where - Answers steel pipe is joined to a dissimilar metal pipe Whenever necessary to make an inspection to enforce any of the provisions of the Code, an authorized representative may enter the premises - Answers at all reasonable times After completion of work and testing of sewer pipeline, who shall request inspection? - Answers Supervisor of job at job-site If the Administrative Authority requests that a new type of material be used on a project, who pays for the testing of the new material? - Answers Contractor When plumbing work is inspected and a "notice of correction" is served, how many days does the contractor have to correct the work? - Answers Within 10 days What is the vertical distance called that is between the lowest opening of a pipe fixture or appurtenance that is discharging waste to the overflow level of a fixture? - Answers Airgap, drainage A cleanout which has direct access without the necessity of removing any panel or door is defined to be - Answers readily accessible Distribution of water from any other source than intended is - Answers backflow Back-siphonage is defined as - Answers the flowing back of used, contaminated or polluted water from a plumbing fixture or vessel into a water supply pipe due to a negative pressure in such pipe The _________________________ is the pipe which carries potable water from a water meter to a building. - Answers building supply Backflow is defined as - Answers non-potable water or other liquids entering a potable water system Any group of two or more similar adjacent fixtures that discharge into a common horizontal waste branch is defined as a - Answers battery Which of the following connects one or more individual vents to a vent stack? - Answers Branch vent A combination waste and vent system may be installed on a _______________________ piping system. - Answers horizontal The minimum level at which a vacuum breaker may be installed above the flood level rim of the device and service is called - Answers the critical level The "the critical level" is shown on a backflow prevention device by a _______________ marking. - Answers C-L or C/L When a backflow prevention device does not bear a "critical level" marking, which part of the device constitutes the critical level? - Answers Bottom What is the Critical Level on a backflow device? - Answers Bottom According to the Uniform Plumbing Code, a "cross connection" is defined as - Answers a connection through which non-potable water may enter a potable water system. What is the name for the measurement taken along the centerline of a pipe and fittings? - Answers Developed length "Existing work" is defined to be a plumbing system or any part thereof which - Answers has been installed prior to the effective date of the code. A pipe which makes an angle of not more than 45 degrees with the horizontal is considered - Answers horizontal A horizontal pipe is any pipe or fitting which is installed in a horizontal position or which makes an angle of less than _________ degrees with the horizontal. - Answers 45 What statement is true about industrial waste? - Answers It is free of fecal matter. The "invert" elevation of a sewer line is the ____________________ of the pipe. - Answers inside bottom Water which is satisfactory for drinking, culinary and domestic purposes and meets the requirements of the health authority having jurisdiction is defined as _____________________ water. - Answers potable Refer to the illustration above. This is a multi-story installation. There is a sink draining into the pipe above "A". What is the name for the pipe at "A"? - Answers soil stack With an on-demand water heater, no relief is required if the maximum inside heater is - Answers 3 " Any liquid waste containing animal or vegetable matter is called - Answers sewage That portion of the drainage system composed of the pipe from the fixture trap to the vent serving that fixture is the _________________________. - Answers trap arm Refer to the illustration above. The trap seal in the illustration above is indicated by dimension - Answers B Refer to the same illustration. The trap seal is the distance from the crown weir (bottom of outlet) to the upper dip and shall not be less than 2 inches nor greater than _______ inches. - Answers 4

Show more Read less
Institution
Journeyman And Master Plumbing
Course
Journeyman and Master Plumbing

Content preview

Journeyman and Master Plumbing Exam Question and Answers Fully Solved

What degree is used for isometric drawings? - Answers 60 degrees

What is the recommended minimum of minutes for chlorine water management? - Answers 20-30
minutes

When you need to repair a single handle lavatory faucet, what needs to be replaced? - Answers O ring

Galvanic corrosion of water supply piping can occur where - Answers steel pipe is joined to a dissimilar
metal pipe

Whenever necessary to make an inspection to enforce any of the provisions of the Code, an authorized
representative may enter the premises - Answers at all reasonable times

After completion of work and testing of sewer pipeline, who shall request inspection? - Answers
Supervisor of job at job-site

If the Administrative Authority requests that a new type of material be used on a project, who pays for
the testing of the new material? - Answers Contractor

When plumbing work is inspected and a "notice of correction" is served, how many days does the
contractor have to correct the work? - Answers Within 10 days

What is the vertical distance called that is between the lowest opening of a pipe fixture or appurtenance
that is discharging waste to the overflow level of a fixture? - Answers Airgap, drainage

A cleanout which has direct access without the necessity of removing any panel or door is defined to be
- Answers readily accessible

Distribution of water from any other source than intended is - Answers backflow

Back-siphonage is defined as - Answers the flowing back of used, contaminated or polluted water from a
plumbing fixture or vessel into a water supply pipe due to a negative pressure in such pipe

The _________________________ is the pipe which carries potable water from a water meter to a
building. - Answers building supply

Backflow is defined as - Answers non-potable water or other liquids entering a potable water system

Any group of two or more similar adjacent fixtures that discharge into a common horizontal waste
branch is defined as a - Answers battery

Which of the following connects one or more individual vents to a vent stack? - Answers Branch vent

A combination waste and vent system may be installed on a _______________________ piping system.
- Answers horizontal

, The minimum level at which a vacuum breaker may be installed above the flood level rim of the device
and service is called - Answers the critical level

The "the critical level" is shown on a backflow prevention device by a _______________ marking. -
Answers C-L or C/L

When a backflow prevention device does not bear a "critical level" marking, which part of the device
constitutes the critical level? - Answers Bottom

What is the Critical Level on a backflow device? - Answers Bottom

According to the Uniform Plumbing Code, a "cross connection" is defined as - Answers a connection
through which non-potable water may enter a potable water system.

What is the name for the measurement taken along the centerline of a pipe and fittings? - Answers
Developed length

"Existing work" is defined to be a plumbing system or any part thereof which - Answers has been
installed prior to the effective date of the code.

A pipe which makes an angle of not more than 45 degrees with the horizontal is considered - Answers
horizontal

A horizontal pipe is any pipe or fitting which is installed in a horizontal position or which makes an angle
of less than _________ degrees with the horizontal. - Answers 45

What statement is true about industrial waste? - Answers It is free of fecal matter.

The "invert" elevation of a sewer line is the ____________________ of the pipe. - Answers inside
bottom

Water which is satisfactory for drinking, culinary and domestic purposes and meets the requirements of
the health authority having jurisdiction is defined as _____________________ water. - Answers potable

Refer to the illustration above. This is a multi-story installation. There is a sink draining into the pipe
above "A". What is the name for the pipe at "A"? - Answers soil stack

With an on-demand water heater, no relief is required if the maximum inside heater is - Answers 3 "

Any liquid waste containing animal or vegetable matter is called - Answers sewage

That portion of the drainage system composed of the pipe from the fixture trap to the vent serving that
fixture is the _________________________. - Answers trap arm

Refer to the illustration above. The trap seal in the illustration above is indicated by dimension - Answers
B

Written for

Institution
Journeyman and Master Plumbing
Course
Journeyman and Master Plumbing

Document information

Uploaded on
April 5, 2025
Number of pages
14
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$10.79
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
450
Member since
1 year
Number of followers
16
Documents
32010
Last sold
2 days ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.5

73 reviews

5
26
4
16
3
14
2
1
1
16

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions