- Name and address of property owner
- Location of property
- Site plan
Applications include: - Type of facility
- Type of water supply
- Number of bedrooms
- Soils information
Any facility having occupancy for ___________ two hours or more
must provide an approved on site sewage
management system
Requirements in permits: Tank size, trench length, depth and width, and special conditions
Absorption field lengths are typically Number of bedrooms or gallons per day, and the percolation rate of the soil
sized by?
Apsorbtion field depths are determined Soil conditions
by?
- Site plan
- Soil report
- Location and elevation of plumbing stub-out
Things to consider when planning layout - Slope of land
of system: - Property lines
- Location of wells, springs, bodies of water, etc. (setbacks)
- Replacement area
- Other conditions
Wells and Springs setback: Septic tank 50 feet
Wells and Springs setback: absorption 100 feet
lines
Property lines setback: Septic tank 10 feet
Property lines setback: absorption lines 50 feet
(private water)
Property lines setback: absorption lines 5 feet
(public water)
Bodies of water or impoundment setback: 25 feet
Septic tank
Bodies of water or impoundment setback: 50 feet
absorption lines
Streams or tributaries setback: Septic tank 25 feet
Streams or tributaries setback: absorption 50 feet
lines
ponded wetland setback: absorption field 50 feet
Buildings with a basement setback: Septic 10 feet
tanks and absorption lines
Buildings without a basement setback: 10 feet
Septic tank