Terms in this set (126)
microbial contamination, excessive bacterial
Patient harmed by
endotoxins, variability in strength of ingredients,
compounded sterile
chemical/physical contaminants, inappropriate
preparations
quality of ingredients
non sterile compounding products used orally, topically on skin or to fill gaps
examples when not commercially available
aesptic state of being free from microbial contamination
injections(iv, etc) ophthalmic drops, aqueous
sterile compounded
bronchial or nasal inhalations, baths for live organs,
items
tissue implants, irrigation for wounds or cavities
Laminar airflow workbench (LAFW) compounding
Non hazardous hoods
containment isolator (CAI)
biological safety cabinet (BSC) compounding
Hazardous hoods
aseptic containment isolator (CACI)
https://quizlet.com/1028111826/ptcb-cspt-exam-2025-update-comprehensive-questions-and-verified-answers-complete-solutions-assured-succe… 1/12
, 4/7/25, 2:31 PM PTCB CSPT EXAM 2025 update| comprehensive questions and verified answers (complete solutions) ASSURED SUCCESS|G…
a device or room that provides an ISO Class 5
environment for the exposure of critical sites when
compounding CSPs. Such devices include, but may
Primary Engineering not be limited to, laminar airflow workbenches
Control (PEC) (LAFWs), biological safety cabinets (BSCs),
compounding aseptic isolators (CAIs), and
compounding aseptic containment isolators
(CACIs).
secondary engineering the ante area and buffer area
controls
Buffer or Clean Room ISO 7
ISO 8, unless provides access to negative pressure
Ante Room ISO class
room then ISO 7
vertical hood hazardous compounding-air flows vertically
air flows horizontally across the work area from
Horizontal Hood
back to front
- a critical area within the hood (ISO Class 5) where
Direct Compounding
areas are exposed to filtered air; also known as "first
Area (DCA)
air"
Negative Pressure room Hazardous materials
High-efficiency remove microbes > 0.3 micrometers
particulate air (HEPA)
filters
Ante Room washing, garbing, product decontamination
Buffer area air change 30 exchanges per hour
per hour (APCH)
ante room air change per ISO 8-20 per hour ISO 7- 30 per hour
hour (APCH)
Cleaning of germicidal detergent & water for visible solids, 70%
compounding area isopropyl alcohol
beginning of each shift, before each batch, every 30
ISO Class 5 PEC cleaned minus when compounding, after spills,
contamination