GAS CFESA PRACTICE TEST EXAM QUESTIONS AND ANSWERS WITH
COMPLETE SOLUTIONS VERIFIED
Terms in this set (100)
The purpose of a draft C
hood/draft diverter is ?
A) To prevent drafts from entering the
burner compartment that comes from the
power cent
hoods.
B)To prevent the combustion chamber
from overheating, and allowing air
to come down the
vent pipe into the room.
C) To allow the flue to control the amount
of secondary air drawn in instead of
the vent pipe,
and to prevent air from coming back
down the vent into the combustion
chamber
D)To allow the vent pipe to control the
amount of secondary air drawn into
the combustion
chamber as designed by its height
above the hood.
1/22
,4/6/25, 9:52 Gas CFESA Practice Test |
AM
The two primary functions of the B
flue are ?
A) The remove combustion byproducts
and heat from the equipment
B)To create a draft to pull in secondary
air and remove the byproducts form
the combustion
chamber
C) To create a draft to keep the
burners cool and remove byproducts
from the cooking area
D)To remove the excessive heat to
keep the burners, and cooking
surface from overheating
To solve unusual venting problems like D
negative pressure, high winds, long vents,
the installe
should use___?
A) A larger size vent pipe
B)Vent outlets
C) Vent top turbines
D) A draft hood
What is a bypass flame? A
A) The smallest flame that will keep
the burners lit after the gas thermostat
has reached the
temperature set point
B)A flame that is 3/8" tall after
the thermostat shuts off
C) A flame left on the burner to keep
the pilot form going out
D) A flame to a special part of the burner
after the main burner goes off
The primary purpose of a vent on a B
regulator is to:
A) Vent leaking gas
B)Allow diaphragm movement
C) Allow high pressure
D) Monitor flow
A properly burning infrared ceramic B
burner will look___?
A) Blue
B) Bright reddish orange
C) Dull red
D) Blue with a tint of orange
Vent lines are required on regulators D
above 1" and must be vented:
A) A pilot flame
B)An open flame within 2 feet
C) A working flue or exhaust system
D)The outside atmosphere, above
the snow line
2/22
, 4/6/25, 9:52 Gas CFESA Practice Test |
AM
What is the proper flame current for an C
ignition module?
A) Always 3 or more microamps
B)Always ¼ or more microamps
C) It depends on the module
manufacturer
D) Always 2 or more microamps
Primary air is the air_____? B
A) That surrounds the burner
B)That enters the burner though
the venture
C) Is the air that is vented through
the exhaust system
D)That must always have a pressure
greater than the incoming gas pressure
Every time a gas fired convection D
oven shuts off the gas flow to the
burners there is a loud pop.
The oven is rated for and using LP
gas. The noise is called , and
can be
reduced by___the
burner air shutters more.
A) Extinction pop, opening
B) Delayed ignition, closing
C) Delayed ignition, opening
D) Extinction pop and by closing
If a leak develops in an LP gas line, where B
is the gas likely to go?
A) Out the exhaust system
B)To the lowest level in the room
C) Up to the ceiling area
D) Out of the kitchen under the door
The approximate amount of BTU's D
produced by burning one cubic foot of
natural gas is?
A) 10,000
B) 2500
C) 750
D) 1000
The normal operating pressure of LP gas C
is___?
A) 10-15 psi
B) 3-7 psi
C) 10-11 in WC"
D) 3-7 in WC"
The normal operating pressure of a D
typical natural gas type burner is
approximately:
A) 15-25 psi
B) 3-4 psi
C) 10-11 in WC"
D) 3.5-7 in WC"
3/22