STANDPIPE SYSTEMS ARE PIPES INSTALLED IN A BUILDING TO TRANSFER WATER
TO ________________ CONNECTIONS LOCATED IN A BUILDING. - (answers)HOSE
IT IS __________ TO INSTALL OR MAINTAIN FIRE PROTECTION SYSTEMS THAT
HAVE THE PHYSICAL APPEARANCE OF FIRE EQUIPMENT BUT THAT DON'T
PERFORM A FUNCTION. - (answers)UNLAWFUL
IT IS THE RESPONSIBILITY OF THE ___________ TO MAINTAIN THE STANDPIPE
SYSTEM. - (answers)OWNER
IN ABSENCE OF A SPECIFIC DESIGNEE, THE BUILDING OWNER SHALL BE
CONSIDERED THE _____________. - (answers)IMPAIRMNENT COORDINATOR
SYSTEMS FULLY OUT OF SERVICE ARE INDICICATED BY A _________ DISC ON FDNY
CONNECTIONS. - (answers)WHITE
SYSTEMS PARTIALLY OUT OF SERVICE ARE INDICATED BY A _________ DISC ON
FDNY CONNECTIONS. - (answers)BLUE
, 2
ONLY FDNY, OWNER, _________ OR __________ MAY PLACE A WHITE OR BLUE
DISC ON A SYSTEM - (answers)MFSPC, MLP
PRIOR TO RETURNING A SYSTEM TO SERVICE, THE ____________ SHALL ENSURE
THAT THE NECESSARY TESTS AND INSPECTIONS ARE CONDUCTED. -
(answers)IMPAIRMENT COORDINATOR
RECORDS SHALL BE ________ AVAILABLE TO ANY REPRESENTATIVE OF THE FIRE
DEPARTMENT. - (answers)READILY
__________ IS A DESIGNED SERIES OF BEAMS USED TO SUPPORT MECHANICAL
EQUIPMENT. - (answers)DUNNAGE
A FIRE DEPT. CONNECTION WAS FORMERLY KNOWN AS A ______________
CONNECTION. - (answers)SIAMESE
THE MEASUREMENT OF SYSTEM PRESSURE UNDER NON-FLOW CONDITIONS IS
__________ PRESSURE. - (answers)STATIC
THE SURGE IN PRESSURE WHEN A HIGH-VELOCITY FLOW OF WATER IS ABRUPTLY
SHUT OFF IS KNOWN AS ____________. - (answers)WATER HAMMER.
VERTICAL PIPING IN STANDPIPE SYSTEMS ARE CALLED ____________. -
(answers)RISERS
S-13 AND S-14 STANDPIPE SYSTEM (2025)
comprehensive questions and verified detailed
solutions ALREADY A+ GRADED HIGHLY
RECOMMENDED|100% CORRECT!!
STANDPIPE SYSTEMS ARE PIPES INSTALLED IN A BUILDING TO TRANSFER WATER
TO ________________ CONNECTIONS LOCATED IN A BUILDING. - (answers)HOSE
IT IS __________ TO INSTALL OR MAINTAIN FIRE PROTECTION SYSTEMS THAT
HAVE THE PHYSICAL APPEARANCE OF FIRE EQUIPMENT BUT THAT DON'T
PERFORM A FUNCTION. - (answers)UNLAWFUL
IT IS THE RESPONSIBILITY OF THE ___________ TO MAINTAIN THE STANDPIPE
SYSTEM. - (answers)OWNER
IN ABSENCE OF A SPECIFIC DESIGNEE, THE BUILDING OWNER SHALL BE
CONSIDERED THE _____________. - (answers)IMPAIRMNENT COORDINATOR
SYSTEMS FULLY OUT OF SERVICE ARE INDICICATED BY A _________ DISC ON FDNY
CONNECTIONS. - (answers)WHITE
SYSTEMS PARTIALLY OUT OF SERVICE ARE INDICATED BY A _________ DISC ON
FDNY CONNECTIONS. - (answers)BLUE
, 2
ONLY FDNY, OWNER, _________ OR __________ MAY PLACE A WHITE OR BLUE
DISC ON A SYSTEM - (answers)MFSPC, MLP
PRIOR TO RETURNING A SYSTEM TO SERVICE, THE ____________ SHALL ENSURE
THAT THE NECESSARY TESTS AND INSPECTIONS ARE CONDUCTED. -
(answers)IMPAIRMENT COORDINATOR
RECORDS SHALL BE ________ AVAILABLE TO ANY REPRESENTATIVE OF THE FIRE
DEPARTMENT. - (answers)READILY
__________ IS A DESIGNED SERIES OF BEAMS USED TO SUPPORT MECHANICAL
EQUIPMENT. - (answers)DUNNAGE
A FIRE DEPT. CONNECTION WAS FORMERLY KNOWN AS A ______________
CONNECTION. - (answers)SIAMESE
THE MEASUREMENT OF SYSTEM PRESSURE UNDER NON-FLOW CONDITIONS IS
__________ PRESSURE. - (answers)STATIC
THE SURGE IN PRESSURE WHEN A HIGH-VELOCITY FLOW OF WATER IS ABRUPTLY
SHUT OFF IS KNOWN AS ____________. - (answers)WATER HAMMER.
VERTICAL PIPING IN STANDPIPE SYSTEMS ARE CALLED ____________. -
(answers)RISERS