And Answers Verified 100% Correct
Condensate is pumped from the condenser to the DC heater instead of directly to the
boiler because __________.
a. boiler feed pumps must operate with a negative suction head
b. suspended solids in the condensate must be eliminated
c. condensate should be deaerated before entering the boiler
d. condensate at condensing temperature is too hot and will cause thermal stress in the
boiler - ANSWER C
Which of the DC heater operations listed will result in excessive dissolved oxygen in
boiler water?
a. Excessively high water level in the heater.
b. Adding excessive make up feed.
c. Operating the heater with a closed air vent.
d. All of the above. - ANSWER D
Under normal conditions, steam to the DC heater is supplied directly from which of the
systems listed? a. Main steam
b. 600 psi auxiliary steam
c. 150 psi auxiliary steam
d. Auxiliary exhaust steam - ANSWER D
Discharging an excessive amount of cold water into the DC heater during normal
steaming conditions could cause __________. a. flashing at the feed pump
suction
b. excess oxygen in the feed water
c. water hammer in the economizer
d. increased back pressure - ANSWER B
The DC heater functions to __________.
a. remove air from feed water
b. heat feed water
c. store feed water
d. all of the above - ANSWER D
, In a closed feed water system, the greatest deaeration of condensate occurs in the
__________. a. DC heater
b. atmospheric drain tank
c. air ejector condenser
d. vent condenser - ANSWER A
The purpose of the steam control valves installed in the auxiliary exhaust line is to
__________.
a. control steam admission and maintain the proper steam spray pattern in the DC
heater
b. regulate back pressure in the desuperheater line
c. preheat the condensate before it enters the vent condenser
d. seal the vent condenser to prevent the escape of condensate - ANSWER A
The minimum design height of the DC heater is determined by the _______.
a. dew point temperature of the stack gases
b. minimum net positive suction head required by the main feed pump
c. maximum condensate pump discharge pressure
d. desuperheater outlet temperature - ANSWER B
Why is it necessary to have a relief valve protect the deaerating feed tank from internal
pressure?
a. Because the tank receives auxiliary exhaust.
b. Because the tank receives high pressure drains.
c. Because the tank receives large amounts of water.
d. Because the tank drains to the main condenser. - ANSWER B
During cold ship start-up, you should open the feed water outlet and condensate valves
to a DC heater in order to __________. a. avoid running the feed pump 'dry'
b. expel non-condensable vapors from the vent
c. thoroughly atomize incoming condensate
d. prevent excessive pressure - ANSWER A
The DC heater automatic level dump valve is used to __________.
a. divert the flow of condensate from the first stage heater to the vent condenser
b. maintain a proper condensate level in the condenser hot well
c. recirculate condensate to the atmospheric drain tank
d. drain excess feed water to the distilled water tank - ANSWER D
Which of the conditions listed may be indicated by the lifting of the DC heater relief