Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Class notes

Switchgear and Protection Circuit Breakers

Rating
-
Sold
-
Pages
9
Uploaded on
26-04-2025
Written in
2024/2025

The document describes and analyses the switching and protection circuit breakers used in electrical power systems

Institution
Course

Content preview

EEE 4508 Switchgear and Protection
Lecture Notes 6
6.0 Switching and Protection Circuit Breakers Cont.:

The circuit breakers that shall be considered in this lecture are the Air blast, Oil, Vacuum,
Metal clad and Sulphur hexa-fluoride types of circuit breakers. The circuit breakers shall be
discussed in their mod of arc extinction and general operation including application.

6.1 Air Blast Circuit breakers

Air blast circuit breakers employ a high-pressure gas blast sweeping across the contacts in the
space so as to create a low resistance arc. The circuit breaker employs gases that are compressed
like; air, nitrogen, carbon dioxide, hydrogen and Freon. Nitrogen has equivalent circuit
breaking properties to compressed air and therefore there is no advantage in using nitrogen.
Carbon dioxide has the drawback of its being difficult to control owing to freezing at valves
and other restricted passages. Tests have shown an increased breaking capacity by the use of
hydrogen, but its cost and that of the ancillary apparatus make its use expensive compared to
air. On the other-hand, Freon has high dielectric strength and good extinguishing properties,
but it is expensive and it is decomposed by the arc into acid forming elements. Therefore, it
follows that compressed air is the accepted circuit-breaking medium for gas-blast circuit
breakers.
6.1.1 Contact Separation
All Air Blast Circuit Breaker follow the principle of separating their contacts in a flow of air
established by the opening of a blast valve. The arc which is drawn is usually rapidly positioned
centrally through a nozzle where it is kept to a fixed length and is subject to maximum
scavenging by the air flow. Arrangements vary but can be grouped into three types as shown
in Figure 6.1:
(i) Axial blast,
(ii) Radial blast
(iii) Cross blast.
Axial and radial blast are preferred for the higher voltages although the cross blast breakers
particularly for voltages of about 15 KV and heavy current (up to 100 KA) have proved to
perform better and require less air than would an axial-blast breaker at these high currents.




1

, Figure 6.1 Air blast circuit breaker
The main structural advantage of the axial-blast circuit breaker over the cross blast is its easier
adaptability to high voltage insulation particularly for outdoor applications. This is because the
interrupting chambers can be fully enclosed in porcelain tubes. The axial blast type of circuit
breaker thus is ideal for high and super voltage application and outdoors where dust and
corrosive fumes are prevalent. In indoor high power medium voltage use, this class of circuit
breaker with currents of 2000-4000A are common, requiring special multi-finger contacts in
order to keep the temperature low enough to prevent damaging through oxidation. A multiple
interruption by air blast can be arranged for very high voltages and combining the joint radial
and axial cooling by direct air convection. In order to secure high air velocities in Air Blast
Circuit Breakers, a relatively short wide passages for the air flow between pressure reservoir
and arc is provided. If the necessary volume of air is available near the arc, velocities exceeding
that of sound may be attained at the critical instant of extinction.

6.1.2 Principle of Operation

Gas blast interruption is dependent on turbulent cooling, and is therefore influenced by
aerodynamic configuration, including nozzles, gas flow passages and mass flow. Compressed
air as an excellent insulator is forced on the arc at the instant of contact separation. The
compressed air acts on the arc through the nozzle which helps exhaust the hot gas and the
arcing products to the atmosphere. In this way the interrupter of an Air Blast Circuit Breaker
performs its operating cycle. Extinction occurs at the first current zero when the flow of
compressed air increases rapidly to establish the dielectric strength between the electrodes to
withstand re-striking voltage. The growth of dielectric strength is rapid and pressure of air is
so high that the final gap caused by interposition of insulating layer of air between the contacts
need only be small, thus reducing the size of the device. The energy supplied for arc extinction
is obtained from high pressure air and is independent of the fault current to be interrupted.


2

Written for

Institution
Course

Document information

Uploaded on
April 26, 2025
Number of pages
9
Written in
2024/2025
Type
Class notes
Professor(s)
Prof. kidegho
Contains
All classes

Subjects

$10.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
clinton2

Get to know the seller

Seller avatar
clinton2 Self
Follow You need to be logged in order to follow users or courses
Sold
-
Member since
1 year
Number of followers
0
Documents
3
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions