Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Refrigeration ESCO Exam Questions and Answers 100% Pass

Beoordeling
-
Verkocht
-
Pagina's
11
Cijfer
A+
Geüpload op
01-05-2025
Geschreven in
2024/2025

©JASONMcCONNELL 2025 ALL RIGHTS RESERVED 1 Refrigeration ESCO Exam Questions and Answers 100% Pass _____ can be used for a leak detection with all high pressure refrigerant - Answersoap bubbles 10 pounds of refrigerant passing through a water cooled condenser will lose 20 BTUs of heat per pound. If 10 pounds of water passes through the condenser with an entering temperature of 80°F the temperature of the water leaving the condenser is - Answer100 degrees a compound pressure gauge measures - Answerpressure and vacuum a compressor that has a broken reed valve will cause these symptoms - Answerhigh suction pressure and low discharge pressure a customer complains that their air conditioning system is running constantly, but not cooling enough. the suction line is very cold and the compressor is sweating, the most likely cause is - Answera restriction of the return air or a dirty evaporator a customer reports that their residential split system had a compressor replaced last week by another service company. Now the unit is not cooling properly. when you arrive and inspect the unit, you find that the evaporator seems to be starved for refrigerant. on examining the condensing unit you find that the liquid line is sweating where it leaves the drier. This is most likely the result of - Answerdebris from the burned out compressor has clogged the drier ©JASONMcCONNELL 2025 ALL RIGHTS RESERVED 2 a decrease in superheat causes the thermostatic expansion valve to begin to - Answerclose A dirty evaporator in an air conditioning system will cause these symptoms - Answerlow suction pressure and low discharge pressure a faulty condenser fan motor on an air conditioning system will cause these symptoms - Answerhigh suction pressure and high discharge pressure a liquid receiver is used to - Answerstore liquid refrigerant a liquid to suction heat exchanger is often used to - Answerincrease liquid subcooling a low pressure cut off switch is used to - Answerestablish minimum operating pressure in the evaporator a low refrigerant charge in an air conditioning system will causes these symptoms - Answerlow suction pressure and low discharge pressure a mechanical shaft seal is necessary on a - Answeropen drive compressor a partially clogged capillary tube can cause - Answera starved evaporator a partially iced over evaporator can be caused by - Answeran undercharge a refrigerant gives up heat when - Answerit condenses A refrigerant overcharge in a capillary tube air conditioning system will cause these symptoms - Answerhigh suction pressure and high discharge pressure

Meer zien Lees minder
Instelling
Refrigeration ESCO
Vak
Refrigeration ESCO

Voorbeeld van de inhoud

©JASONMcCONNELL 2025 ALL RIGHTS RESERVED




Refrigeration ESCO Exam Questions and
Answers 100% Pass




_____ can be used for a leak detection with all high pressure refrigerant - Answer✔soap
bubbles


10 pounds of refrigerant passing through a water cooled condenser will lose 20 BTUs of heat
per pound. If 10 pounds of water passes through the condenser with an entering temperature
of 80°F the temperature of the water leaving the condenser is - Answer✔100 degrees



a compound pressure gauge measures - Answer✔pressure and vacuum



a compressor that has a broken reed valve will cause these symptoms - Answer✔high suction
pressure and low discharge pressure


a customer complains that their air conditioning system is running constantly, but not cooling
enough. the suction line is very cold and the compressor is sweating, the most likely cause is -
Answer✔a restriction of the return air or a dirty evaporator


a customer reports that their residential split system had a compressor replaced last week by
another service company. Now the unit is not cooling properly. when you arrive and inspect the
unit, you find that the evaporator seems to be starved for refrigerant. on examining the
condensing unit you find that the liquid line is sweating where it leaves the drier. This is most
likely the result of - Answer✔debris from the burned out compressor has clogged the drier



1

, ©JASONMcCONNELL 2025 ALL RIGHTS RESERVED


a decrease in superheat causes the thermostatic expansion valve to begin to - Answer✔close



A dirty evaporator in an air conditioning system will cause these symptoms - Answer✔low
suction pressure and low discharge pressure


a faulty condenser fan motor on an air conditioning system will cause these symptoms -
Answer✔high suction pressure and high discharge pressure



a liquid receiver is used to - Answer✔store liquid refrigerant



a liquid to suction heat exchanger is often used to - Answer✔increase liquid subcooling



a low pressure cut off switch is used to - Answer✔establish minimum operating pressure in the
evaporator


a low refrigerant charge in an air conditioning system will causes these symptoms -
Answer✔low suction pressure and low discharge pressure



a mechanical shaft seal is necessary on a - Answer✔open drive compressor



a partially clogged capillary tube can cause - Answer✔a starved evaporator



a partially iced over evaporator can be caused by - Answer✔an undercharge



a refrigerant gives up heat when - Answer✔it condenses


A refrigerant overcharge in a capillary tube air conditioning system will cause these symptoms -
Answer✔high suction pressure and high discharge pressure

2

Geschreven voor

Instelling
Refrigeration ESCO
Vak
Refrigeration ESCO

Documentinformatie

Geüpload op
1 mei 2025
Aantal pagina's
11
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
StarGuide Liberty University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
21
Lid sinds
1 jaar
Aantal volgers
0
Documenten
2588
Laatst verkocht
1 week geleden
FIRST CLASS GALORE

Accurate Exam Study Materials.Verified And Updated By Professionals.

4.3

4 beoordelingen

5
1
4
3
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen