ANSWERS (RATED A+)
Low airflow over a residential split system air conditioning evaporator can cause
A: Liquid flood-back to the compressor
B: A decrease in compression ratio
C: An increase in suction line superheat
D: Oil logging in the evaporator - ANSWERA: Liquid flood-back to the compressor
All else being normal, if a system shows a high lowside superheat with low condenser
subcooling, what is most likely the problem?
A: Refrigerant overcharge
B: Refrigerant undercharge
C: A partial restriction
D: There is probably no problem - ANSWERB: Refrigerant undercharge
A grille equipped with a damper control is called
A: A vane
B: A register
C: A louver
D: A damper - ANSWERB: A register
As the pressure on a liquid is increased, the vaporization temperature of the liquid
A: Decreases
B: Increases
C: Remains unchanged
, D: Varies - ANSWERB: Increases
An oil separator must be mounted
A: Level
B: Below the compressor crankcase
C: Above the compressor crankcase
D: In the suction line - ANSWERA: Level
Which of the following metering devices controls evaporator pressure?
A: Thermostatic expansion valve
B: Fixed orifice
C: Low side float
D: None of these - ANSWERD: None of these
An automatic expansion valve controls evaporator pressure.
The purpose of the external equalizer on a thermostatic expansion valve is
A: To equalize evaporator pressure drop with respect to the TEV
B: To equalize the evaporator pressure drop
C: To help prevent liquid floodback
D: To allow the high side pressure to equalize to the low side when the compressor
cycles off - ANSWERA: To equalize evaporator pressure drop with respect to the TEV
The higher the MERV rating of a filter-drier, the
A: More efficient the drier at absorbing moisture
B: Less efficient the drier at absorbing moisture
C: Smaller the particles the filter can entrap
D: MERV does not apply to filter-driers - ANSWERD: MERV does not apply to filter-
driers