NBRC TMC1 TEST BANK EXAM NEWEST VERSION WITH
COMPLETE QUESTIONS AND CORRECT DETAILED
ANSWERS \\ACTUAL EXAM WITH VERIFIED ANSWERS
ASSURED PASS GRADED A+ \\BRAND NEW!
1. A Bennett PR-II with a 1.Tighten the humidifier jar and lid.
Cascade-type humidifier 3.Tighten the medication nebulizer jar and manifold.
and modified IPPB circuit
is being used to deliver
an aerosolized
medication and ventilate a
patient in the recovery
room. When the
respiratory
therapist checks the patient
and ventilator, it is noticed
that the inspiratory time is
longer than when first charted
and the
machine does not cycle off
until the patient blows out.
What should be done to
correct the problem?
1. Tighten the humidifier jar and
lid.
2. Increase the control
pressure.
3. Tighten the medication
nebulizer jar and manifold.
4. Pull the air-dilution knob
out from the body of the
machine.
1/108
,5/10/25, 3:12 PM NBRC TMC1
2. When assisting with the A. The larynx can be palpated as the tube is inserted.
intubation of a neonate's
airway, what is the first thing
that can be assessed to
determine whether or not
the tube has been placed
into the
trachea?
A. The larynx can be
palpated as the tube is
inserted.
B. There will be a change in
the sound of the
neonate's cry.
C. Bilateral lung sounds can be
heard.
D. The chest will rise
when a breath is
delivered by manual
resuscitator.
3.A 50-year-old patient is B. Increasing the tidal volume
being
mechanically ventilated and
needs an
increase in alveolar
ventilation. What is the best
way to accomplish this?
A. Adding therapeutic PEEP
B. Increasing the tidal volume
C. Increasing the rate
D. Increasing the flow
2/108
,5/10/25, 3:12 PM NBRC TMC1
4. A decision is made to C. Take off the corrugated tubing.
switch a stable patient
from a wick-type
humidifier to a heat
moisture exchanger.
Two
sections of corrugated tubing
(12 inches)
are used to connect the
HME between the circuit Y
and the endotracheal
tube. After an hour, the
following arterial blood gas
values are obtained:
pH7.32
PaCO 2 54 torr
PaO 2 68 torr
HCO 3 - 24 mEq/L
BE 0 mEq/L
SaO 2 92%
A. Recheck the blood gas
results.
B. Increase the
inspired oxygen
percentage.
C. Take off the corrugated
tubing.
D. Change back to the wick-
type humidifier.
5. When a respiratory 1. Replace the washer between the regulator and the cylinder
therapist cracks open an E- system valve.
3. Tighten the regulator onto the cylinder valve system.
cylinder, a loud hissing sound
is heard, and gas can be felt
leaking from the
regulator despite the fact
that the flow meter has
been turned off. What can
be done to correct this
problem?
1. Replace the washer between
the
3/108
, 5/10/25, 3:12 PM NBRC TMC1
regulator and the cylinder
system valve.
2. Turn on the flow meter.
3. Tighten the regulator
onto the cylinder valve
system.
4. Change the type of
regulator.
A patient is receiving
6. C. Measure a before-and-after bronchodilator FEV 1 .
aerosolized
bronchodilators to treat her
asthma. What is the best way
to determine whether the
medication is having a
positive effect?
A. Measure the patient's VC.
B. Measure the patient's
MIP after the medication
has been delivered.
C. Measure a before-
and-after
bronchodilator FEV
1.
D. Calculate the patient's
minute alveolar
ventilation.