2025/2026 exam WITH COMPLETE
QUESTIONS AND SURE VERIFIED
SOLUTIONS 100% GRADED AT A+
SCORE SURE GUARANTEED PASS!!
1. Amtrak Conductors and Engineer are classified as class ______
employees - ANSWER ✓ C. [1.103]
2. Conductive material such as steel tape measure, wire, wet or non-
rated rope, or linen tape-line containing metallic reinforcement can
be used around energized wire, apparatus, equipment, or third rail.
True or False? - ANSWER ✓ False. [1.114]
3. The Minimum Approach Distance for AMT-2 Qualified Employees
whether or not protected by Class A employee against
Transmission Wires energized or de-energized and not grounded
is? - ANSWER ✓ 8ft. [Table 1]
4. What is the Minimum Approach Distance for AMT-2 Qualified
Employee whether or not protected by a Class A employee against
the Catenary, Signal Line, and Utility Wires less than 35000 volts,
, energized or de-energized and not grounded? - ANSWER ✓ 3ft.
[Table 1]
5. Should employees in electrified territory be familiar with the
location and operation of radios and telephones? - ANSWER ✓
Yes [1.204]
6. When using railroad telephone lines or radios, and you hear the
word "EMERGENCY" repeated three times, what must be done? -
ANSWER ✓ All others using the phone line or radio channel must
yield immediately. [1.205]
7. All occurrences or conditions which are likely to affect electric
Operations must be reported immediately to whom? - ANSWER ✓
The Power Director/Train Dispatcher. [1.201]
8. Minimum Approach Distance means? - ANSWER ✓ The distance
that must be maintained between personnel and or equipment and
all exposed energized lines. Minimum Approach Distance is
measured between the person or the end of a tool, equipment, or
material being used and the exposed energized parts. [1.301]
9. All overhead wires must be considered energized (Live) at all
times except? - ANSWER ✓ When it is known to be de-energized,
tested de-energized and grounded. [1.302]
, 10. The third rail must be considered energized (live) at all times
except? - ANSWER ✓ When it is known to be de-energized, tested
de-energized and a Third Rail Warning Device is applied. [1.303]
11. Electric engines and Multiple Units (MU) under overhead
wires must be considered energized (Live) except? - ANSWER ✓
When it is known that all Pantographs are down and Pantograph
grounding switches are closed, or overhead wires are de-energized,
tested de-energized and properly grounded. [1.501]
12. Can employees touch or remove unidentified dangling wires,
trees, or foreign objects in contact with overhead wires or third
rail? - ANSWER ✓ NO ,employees must take necessary
precautions to protect others and equipment and maintain
Minimum Approach Distance . [1.206]
13. What is the Minimum Approach Distance for AMT-2
Qualified Employees against Transmission Wires for equipment
operating in the vicinity of wires energized or de-energized and not
grounded? - ANSWER ✓ 15ft. [Table 1]
14. The Minimum Approach Distance for AMT-2 Qualified
Employees against Catenary, Signal Line, Utility Wires Less than
35000 volts for Equipment operating in the vicinity of wires