Questions and 100% Verified Correct Answers
Guaranteed A+
A ladder is required in a trench at what depth - CORRECT ANSWER: 4ft or deeper
A pneumatic tamper and pavement breaker tamping foot is needed for what size lifts -
CORRECT ANSWER: 6in
A vibratory plate compactor and percussive whacker rammer on what size lists -
CORRECT ANSWER: 6in-12in
Always call what before any excavation - CORRECT ANSWER: 811
An abnormal operating condition may include - CORRECT ANSWER: Malfunction of a
component, deviation from normal operating conditions
An uncontrolled escape of gas during the performance of a covered task - CORRECT
ANSWER: Keep area safe/public at safe distance of 25ft, check if windows are open on
houses/buildings in the area, notify dispatcher, consider the need to turn off utilities from
outside, eliminate ignition sources
An uncontrolled ignition of gas while performing a covered task - CORRECT ANSWER:
Secure area 25ft min, protect property and lives, notify dispatch, let fire burn if no further
damage is possible, call for help, get gas shut off at curb/meter valve, notify emergency
services, contact incident commander for uncontrolled ignition, where fire ppe
Anytime excavation that is planned within 200ft of a few or gate station what has to
happen - CORRECT ANSWER: Call gas control and regulation department