Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Advanced Fetal Monitoring EXAM 2025 | ALL CURRENT EXAM VERSIONS 2025 | ACCURATE REAL EXAM QUESTIONS AND ANSWERS | ACCURATE AND VERIFIED FOR GUARANTEED PASS | GRADED A QUESTIONS

Beoordeling
-
Verkocht
-
Pagina's
28
Cijfer
A+
Geüpload op
13-05-2025
Geschreven in
2024/2025

1. Limitations to internal EFM include: A. Required ROM B. SVE required C. Slight increased risk of infection D. May half FHR 180 E. May record MHR in the case of a fetal demise F. All of the above G. All except D Correct Answer: F. All of the above Rationale: Internal EFM requires rupture of membranes (ROM), may carry a slight increased risk of infection, may inaccurately record maternal heart rate (MHR), and it could register a heart rate lower than expected. 2. External Fetal Monitoring for uterine activity includes: Correct Answer: Tocodynamometer and Intrauterine Pressure Catheter Rationale: These are the devices used for external monitoring of uterine activity. 3. Limitations of a TOCO include: Correct Answer: May need readjusting and cannot determine intensity or resting tone Rationale: The tocotransducer can shift during monitoring and does not measure the intensity or resting tone of contractions. 4. Limitations of IUPC include: Correct Answer: ROM required, slight increased risk of infection, and (rare) risk of causing placental separation/uterine trauma Rationale: Intrauterine pressure catheter (IUPC) requires rupture of membranes and may introduce infection or other risks, including placental separation. 5. What does legal standard of care mean? Correct Answer: What any professional with the same or similar background, education, and training would do under the same or similar circumstances. Rationale: Legal standard of care is defined by what other professionals with similar training and education would do in a similar situation. 6. Position Statement: FHR monitoring requires ___________________ and __________________ skills. Correct Answer: advanced assessment and clinical judgement Rationale: FHR monitoring requires the ability to assess and make clinical decisions based on that data. 7. Position Statement: FHR monitoring should ___ be delegated to ____________________ or others that do not possess the appropriate licensure, education, and skill validation. Correct Answer: not, unlicensed personnel Rationale: FHR monitoring requires professional expertise and cannot be delegated to unlicensed personnel. 8. Position Statement: Women's __________ and _____________________ should guide selection of FHR monitoring techniques. Correct Answer: preference, and clinical presentation Rationale: A woman’s preferences and clinical condition should determine the choice of monitoring technique. 9. Position Statement: Avoid describing the FHR patterns. Use _____ terminology. Correct Answer: NICHD Rationale: The National Institute of Child Health and Human Development (NICHD) provides standard terminology for describing fetal heart rate patterns. 10. Position Statement: It is within the scope of practice of the nurse to implement customary _____________ in response to FHR ____________ and ___________________. Correct Answer: interventions, monitoring data, and clinical assessment Rationale: Nurses are responsible for implementing interventions based on monitoring and clinical data. 11. Position Statement: Interprofessional policies should support the RN in making decisions regarding fetal monitoring practice and _________________________ when appropriate to maternal and fetal conditions. Correct Answer: intervening independently Rationale: Nurses should be supported in making independent decisions when necessary for maternal and fetal health. 12. Position Statement: Chain of Authority (command) is used to _________ the best interests of the _____, ____, and members of the ________________. Correct Answer: safeguard, woman, baby, health care team Rationale: The chain of command ensures the well-being of the woman, fetus, and healthcare team members. 13. What are suggestions for conflict resolution? Correct Answer: Consult with a colleague, discuss concerns with provider, discuss concerns with nurse manager/supervisor, follow chain of command Rationale: Resolving conflicts in healthcare requires communication with colleagues and supervisors and following the chain of command. 14. Orders should be... Correct Answer: Specific and understandable Rationale: Orders must be clear to ensure proper action and understanding. 15. There should be a systematic assessment of woman and fetus. When an abnormal finding occurs, assessment and plans should be... Correct Answer: determined and documented Rationale: Abnormal findings must be addressed with clear plans and documentation. 16. Documentation should occur ____________ when utilizing auscultation, as there is no __________ record. Correct Answer: concurrently and electronic Rationale: Documentation should happen in real-time to avoid inaccuracies and ensure the electronic record is accurate. 17. Any communication with any provider should be... Correct Answer: Documented! Rationale: Communication with healthcare providers must always be documented to ensure a clear record of care. 18. Two limitations of the ultrasound transducer are: A. It is invasive and can cause infection B. It may half-count the FHR and it can double-count the FHR C. It will not count MHR and record maternal respirations Correct Answer: B. It may half-count the FHR and it can double-count the FHR Rationale: The ultrasound transducer can miscount the fetal heart rate, either by halving or doubling it.

Meer zien Lees minder
Instelling
Advanced Fetal Monitoring
Vak
Advanced Fetal Monitoring

Voorbeeld van de inhoud

Advanced Fetal Monitoring EXAM 2025 |
ALL CURRENT EXAM VERSIONS 2025 |
ACCURATE REAL EXAM QUESTIONS AND
ANSWERS | ACCURATE AND VERIFIED FOR
GUARANTEED PASS | GRADED A
QUESTIONS
1. Limitations to internal EFM include:

A. Required ROM
B. SVE required
C. Slight increased risk of infection
D. May half FHR <180
E. May record MHR in the case of a fetal demise
F. All of the above
G. All except D

Correct Answer: F. All of the above
Rationale: Internal EFM requires rupture of membranes (ROM), may carry a slight increased risk of
infection, may inaccurately record maternal heart rate (MHR), and it could register a heart rate lower
than expected.



2. External Fetal Monitoring for uterine activity includes:

Correct Answer: Tocodynamometer and Intrauterine Pressure Catheter
Rationale: These are the devices used for external monitoring of uterine activity.



3. Limitations of a TOCO include:

Correct Answer: May need readjusting and cannot determine intensity or resting tone
Rationale: The tocotransducer can shift during monitoring and does not measure the intensity or resting
tone of contractions.



4. Limitations of IUPC include:

,Correct Answer: ROM required, slight increased risk of infection, and (rare) risk of causing placental
separation/uterine trauma
Rationale: Intrauterine pressure catheter (IUPC) requires rupture of membranes and may introduce
infection or other risks, including placental separation.



5. What does legal standard of care mean?

Correct Answer: What any professional with the same or similar background, education, and training
would do under the same or similar circumstances.
Rationale: Legal standard of care is defined by what other professionals with similar training and
education would do in a similar situation.



6. Position Statement: FHR monitoring requires ___________________ and __________________
skills.

Correct Answer: advanced assessment and clinical judgement
Rationale: FHR monitoring requires the ability to assess and make clinical decisions based on that data.



7. Position Statement: FHR monitoring should ___ be delegated to ____________________ or others
that do not possess the appropriate licensure, education, and skill validation.

Correct Answer: not, unlicensed personnel
Rationale: FHR monitoring requires professional expertise and cannot be delegated to unlicensed
personnel.



8. Position Statement: Women's __________ and _____________________ should guide selection of
FHR monitoring techniques.

Correct Answer: preference, and clinical presentation
Rationale: A woman’s preferences and clinical condition should determine the choice of monitoring
technique.



9. Position Statement: Avoid describing the FHR patterns. Use _____ terminology.

Correct Answer: NICHD
Rationale: The National Institute of Child Health and Human Development (NICHD) provides standard
terminology for describing fetal heart rate patterns.



10. Position Statement: It is within the scope of practice of the nurse to implement customary
_____________ in response to FHR ____________ and ___________________.

, Correct Answer: interventions, monitoring data, and clinical assessment
Rationale: Nurses are responsible for implementing interventions based on monitoring and clinical data.



11. Position Statement: Interprofessional policies should support the RN in making decisions regarding
fetal monitoring practice and _________________________ when appropriate to maternal and fetal
conditions.

Correct Answer: intervening independently
Rationale: Nurses should be supported in making independent decisions when necessary for maternal
and fetal health.



12. Position Statement: Chain of Authority (command) is used to _________ the best interests of the
_____, ____, and members of the ________________.

Correct Answer: safeguard, woman, baby, health care team
Rationale: The chain of command ensures the well-being of the woman, fetus, and healthcare team
members.



13. What are suggestions for conflict resolution?

Correct Answer: Consult with a colleague, discuss concerns with provider, discuss concerns with nurse
manager/supervisor, follow chain of command
Rationale: Resolving conflicts in healthcare requires communication with colleagues and supervisors and
following the chain of command.



14. Orders should be...

Correct Answer: Specific and understandable
Rationale: Orders must be clear to ensure proper action and understanding.



15. There should be a systematic assessment of woman and fetus. When an abnormal finding occurs,
assessment and plans should be...

Correct Answer: determined and documented
Rationale: Abnormal findings must be addressed with clear plans and documentation.



16. Documentation should occur ____________ when utilizing auscultation, as there is no __________
record.

Geschreven voor

Instelling
Advanced Fetal Monitoring
Vak
Advanced Fetal Monitoring

Documentinformatie

Geüpload op
13 mei 2025
Aantal pagina's
28
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
lisarhodes411 HARVARD
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
30
Lid sinds
1 jaar
Aantal volgers
1
Documenten
1768
Laatst verkocht
1 maand geleden

3.8

6 beoordelingen

5
1
4
3
3
2
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen