E-30.13.1 All power cables shall be_____ against chafe and physical
damage by installation in conduit, dedicated cable trays, or by cable
clamps or other secure methods which meet the requirements of
ABYC E-11, AC and DC Electrical Systems on Boats. - ----
Answers_---protected


E-30.13.2 High current conductors for the propulsion system shall not
be______ in the same wiring system as the vessel's AC or DC
circuits, unless one of the following methods of separation is used: - --
--Answers_---contained


E-30.13.2 High current conductors for the propulsion system shall not
be contained in the same wiring system as the vessel's AC or DC
circuits, unless one of the following methods of separation is used: E-
30.13.2.1 installed in a physically________ conduit or cable tray or, -
----Answers_---separate


E-30.13.2 High current conductors for the propulsion system shall not
be contained in the same wiring system as the vessel's AC or DC
circuits, unless one of the following methods of separation is used: E-
30.13.2.2 installed on a tray or ladder where physical separation is
provided by a________, or - ----Answers_---partition


E-30.13.2 High current conductors for the propulsion system shall not
be contained in the same wiring system as the vessel's AC or DC
circuits, unless one of the following methods of separation is used: E-

,30.13.2.3 fixed directly to the surface and separated by at least _
inches (100mm). - ----Answers_---4


E-30.13.3 Dedicated motor inverter/controller power conductors,
between the inverter/controller and motor shall be designed and
installed to minimize conducted or radiated electromagnetic______. -
----Answers_---emissions


E-30.13.4 All connections, other than to batteries and circuits under
60 VDC, shall be made in __________ enclosures or the connections
themselves shall be fire resistant. - ----Answers_---self-extinguishing


E-30.13.5 Self-limited power supplies shall be________ with a
maximum current output available. For power supplies not so labeled,
see ABYC E-11, AC and DC Electrical Systems on Boats for required
circuit protection requirements. - ----Answers_---labeled


E-30.13.6 Conductors should be permanently identified within at least
_ inches (152.5 mm) of the end of the conductor as to voltage and
purpose (see ABYC E-11.) - ----Answers_---6


E-30.13.7 All panelboards and switchboards should be protected as
follows: LOCATION IP ENCLOSURE RATING, Interior __ - ----
Answers_---N/A


E-30.13.7 All panelboards and switchboards should be protected as
follows: LOCATION IP ENCLOSURE RATING, Machinery___ - ---
-Answers_---IP55

,E-30.13.7 All panelboards and switchboards should be protected as
follows: LOCATION IP ENCLOSURE RATING, Wet____ - ----
Answers_---IP56


E-30.13.7 All panelboards and switchboards should be protected as
follows: LOCATION IP ENCLOSURE RATING, Damp____ - ----
Answers_---IP44


E-30.13.8 All conductors shall meet the requirements of: E-30.13.8.1
_____, National Electric Code, or - ----Answers_---NFPA 70


E-30.13.8 All conductors shall meet the requirements of: E-
30.I3.8.2_______, High Voltage Primary Cable, or - ----Answers_---
SAE J 1654


E-30.13.8 All conductors shall meet the requirements of: E-30.13.8.3
________, Electrical Installations in Ships - Part 353: Power cables
for rated voltages 1 kV and 3 kV, or - ----Answers_---IEC 60092.353


E-30.13.8 All conductors shall meet the requirements of: E-30.13.8.4
I________, Recommended Practice for Electric Installations on
Shipboard. - ----Answers_---EEE 45


E-30.13.9 Conductor sizes shall be selected from TABLE 1, or
according to the equipment ___________ specifications. - ----
Answers_---manufacturer's

, E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1 _______ data
including: - ----Answers_---Battery group


E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.1 _________ - ----
Answers_---battery technology/type


E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.2 prospective
___________ in amperes - ----Answers_---short circuit current


E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.3 ________ and
temperature requirements - ----Answers_---ventilation


E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.3 ventilation and
_______ requirements - ----Answers_---temperature


E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.1.4 ________ - ----
Answers_---amp hours


E-30.14.1 The following minimum data shall be included in the
system installation documentation: E-30.14.1.2 ________ data
including: - ----Answers_---Generator

Written for

Institution
ABYC ADVANCED PRETEST
Course
ABYC ADVANCED PRETEST

Document information

Uploaded on
May 19, 2025
Number of pages
67
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SCHOLARSKIT Chamberlain School Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
293
Member since
1 year
Number of followers
7
Documents
7617
Last sold
11 hours ago
SCHOLARS KIT

Welcome To my Store My Goal is to help you achieve your desired grades by providing credible study materials I'm happy to help you with quality documents On this page you will find quality study guides,Exams assignments, Research papers and Test Banks all verified correct . you'll find past and recent revised and verified study materials . Stay here and You'll find everything you need to pass !!! . I always ensure my documents are of high standards I am always available to assist 24/7 and answer any queries you may have . Be assured to get good grades and always leave a review after a purchase Refer a friend SUCCESS!!!!

Read more Read less
3.7

59 reviews

5
26
4
8
3
13
2
3
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions