Actual Exam Questions With Reviewed 100%
Correct Detailed Answers
Guaranteed Pass!!Current Update
(Verified Pass)
1. When two piece Dosing tanks are used sections must be
_______________by using mastic, butyl rubber, or other pliable sealant
that is water proof, corrosion resistant and approved for use in septic tanks.
- ANSWER Joined
2. For Dosing tanks, there shall be no requirement as to
_____________,_____________,or ___________ of tank. - ANSWER
length, width, of shape
3. Tanks may have a single compartment or if a partition is used it must have
_______________________________________ located no more than
________inches above the tank bottom. - ANSWER 2 four inch diameter
holes or equivalent,
12 inches
4. Dosing tanks using PUMPS must have a reserve capacity of
_______________ flow. - ANSWER One days
, 5. True or False: Dosing tanks for SIPHONS will not be required to have one
days flow reserved. - ANSWER True
6. True or False: All tanks must have an operating liquid capacity of 60%-70%
the interior volume of the absorption lines to be dosed. - ANSWER True
7. All dosing tanks shall have switches and alarms that notify the owner of
_____________________. - ANSWER malfunction.
8. When determining dosing tank requirements _____________,
_________________, _________________, and ____________________
should be taken into consideration. - ANSWER volume, flow rates, waste
water characteristics, and other similar information
9. True or False: Large capacity dosing tanks will need to be constructed on
site. - ANSWER True
10.Dosing tanks shall have a water-tight access cover at least ____________
inches in diameter extending to the ground or no more than
______________ inches below the ground surface. - ANSWER 24
inches,
12 inches
11.When pumps are used to does field lines, consideration must be given to
the _____________________, ________________________, and