PRACTICE EXAM WITH ALL CORRECT &
VERIFIED ANSWERS
Should be applied over continuous or closely spaced wood plank decking/wood decking. Correct
answer-As a recommendation, asphalt shingles:
is not recommended Correct answer-Torch-application of modified bitumen membrane sheet
directly to a wood deck:
open framing Correct answer-Steep slope structural roofs are mostly applied over:
are thick Correct answer-Laminate shingles
bar joists Correct answer-Low slope metal roofs may be applied DIRECTLY over :
EPDM (Ethylene Propylene Diene Terpolymer) Correct answer-Which of the following is a highly
common category of thermoset roof membrane?
is not expensive Correct answer-built-up roofing (BUR)
not compatible with asphalt products Correct answer-Polyvinyl Chloride (PVC) aka. vinyl roofing is
mostly use plate fastenings and has trusses occurring at regular intervals Correct answer-Roof
trusses
Chapter 15- Roof Assemblies & Rooftop Structures Correct answer-The majority of IBC's 2015's
roofing-related requirements are available in which chapter?
FALSE. Both ASTM E1592 & FM 4474 may be used for structural standing-seam metal panel systems
without exposed fasteners. (IBC 2015) Correct answer-ONLY FM 4474 can be used for testing
structural standing-seam metal panel systems without exposed fasteners.
are durable and generally affordable Correct answer-Composite Shingles ( composed of asphalt &
fiberglass)
3 1/2 to 7 1/2 (Steep Pitched Roofs are greater than 7 1/2) Correct answer-Medium Pitched Roofs
have a pitch range between
EPDM (used in single ply roof membrane) Correct answer-ASTM D4637 is a standard specification
that covers
may be considered Class A without testing Correct answer-Per IBC, Copper Sheet Roofing(min.
16oz) over combustible roof deck
TRUE. They are not compatible. (PVC is made up of ethylene and chlorine, and more durable than
EPDM) (Perlite roofing is often used for insulation) Correct answer-Perlite and PVC membranes
Primarily comes in black, has poor solar reflectivity, may be laminated with an additional layer.
(addition layer may not be as durable) Correct answer-Rubber Roofing
, BUR ( Built-Up Roofing) Correct answer-Which of the following is commonly referred to as "tar and
gravel" roof?
FALSE. The Architect will almost always be held vicariously liable. Correct answer-The building
owner will almost always be held vicariously liable when a design's nonconformance with the
building code exists.
Solid deck (solid sheathing/ solid decking) Correct answer-A _____ deck would be considered as a
must in seismic activity, hurricane and tornado regions.
can increase the roofs insulation value Correct answer-A felt interlay
Asphalt Shingles, Clay and Concrete Tile, Metal for steep slope, Slate, Wood shakes and wood
shingles, Synthetic Correct answer-Which of the following are classifications of steep slope roof
coverings?
should be capped, may be site-made or factory-made as long as they come with alternate overlaps
and concealed nailing. Correct answer-The intersecting roof surfaces at hips and ridges
EVERY steep-slope covering (prior to roof covering application) Correct answer-Underlayment's
should be used with
ASTM D6757-02 Correct answer-Which of the following is a standard that addresses the
requirements for fiberglass- or fiberglass-composite- reinforced underlayment products?
should NOT be applied with their grain parallel to the valley centerline. For those extending into the
valley, make sure they are cut at the correct angle. Correct answer-For roofs with valleys, shingles:
Class A and 1 hour fire resistant construction requirements. Correct answer-APA-rated plywood
can be used to meet
Felt interlay. It can also force water to the surface. Correct answer-Which of the following can act
as a baffle to prevent wind- driven snow or other foreign material from entering the attic cavity?
have low R-values, can hardly be used by themselves Correct answer-Perlite and wood fiber:
1/4 inches per foot Correct answer-The minimal allowable size of slope for perfect drainage at the
roof is:
Per NFPA 5000, there are specific requirements for buildings roof assemblies in that they need to be
hail-resistant in specific hail-prone regions. Correct answer-Referring to the NFPA, there are
requirements spelled out for buildings' roof assemblies in hail-prone regions:
there is heavy traffic on the roof. They are thicker. Correct answer-Built-up roofs are suitable when
NEVER allow the installation of a new roof system over existing roof systems with wet insulation.
Correct answer-Model building codes
deploys interlocking panels Correct answer-Low slop structural roofing