CAMRT PRACTICE EXAM CERTIFIED QUESTIONS AND Answers Verified 100% Correct The air kerma rate must not exceed ___ from scattered radiation of radioscopic equipment - CORRECT ANSWER- 2 mGy/h How frequently should IP's and cassettes be cleaned and inspected? - CORRECT ANSWER- Cleaned: monthly Visual inspection: Weekly What are daily QC tests for CR/DR/Fluoro/CT equipment - CORRECT ANSWER- - Warm up (all) -Meter operation (all) -Equipment condition (all) -System movements (fluoro) -Visual assessment of electronic display devices (all) What are weekly QC tests for CR/DR/Fluoro/CT equipment - CORRECT ANSWER- - Visual inspection of cleanliness of system (all) -Laser film printer operation (all) -CT # accuracy -CT noise -CT uniformity HVL of Aluminum for given tube voltages? (70kV - 150 kV) - CORRECT ANSWER - 70: 2.5 m m m 80: 2.9 m 90: 3.2 m m mm 100: 3.6 110: 3.9 mm 120: 4.3 mm 130: 4.7 m m 140: 5.0 mm 150: 5.4 mm What are monthly QC tests for CR/DR/Fluoro/CT equipment - CORRECT ANSWER- - Cassette, screen, IP plate cleaning (CR) -Retake analysis (CR/DR) -Electronic display device performance (all) -Laser film printer operation (all) -CT slice thickness -CT # calibration -CT # linearity What should the monthly retake analysis be below? - CORRECT ANSWER- 5% What are quarterly QC tests for CR/DR/Fluoro/CT - CORRECT ANSWER- -Collimator operation (CR/DR/Fluoro) -Interlocks (all) (on doors to prevent exposure if door is open) -Compression devices (Fluoro) -Table angling/motion (Fluoro) -Fluoro protection devices (lead drapes = .25mm of pb) -CT patient support movement -CT spatial resolution -CT low contrast detectability What are the annual QC tests for CR/DR/Fluoro/CT - CORRECT ANSWER- -Accuracy of loading factors (CR/DR/fluoro) -Output reproducibility -Output linearity -Beam filtration -AEC -Beam/light field alignment - Beam collimation -Grid performance -EI -Dynamic Range -Spatial resolution -Integrity of protective equipment Flexion/ Extension views of the C spine assess? - CORRECT ANSWER- Anteroposterior mobility CR angle for an AP coccyx is - CORRECT ANSWER- 10 degrees caudad What does ERCP stand for, what 2 things is it done for? - CORRECT ANSWER- Endoscopic Retrograde Cholangiopancreatography 1. Diagnose biliary and pancreatic pathological conditions 2. Investigate gallbladder, CBD, pancreatic ducts, and intervention Test tool used to test focal spot - CORRECT ANSWER- Slit camera, pinhole camera, star pattern State the line focus principle - CORRECT ANSWER- By angling the anode target the effective focal spot is made much smaller than the actual focal spot What are the effects of a smaller anode angle? (more vertical) - CORRECT ANSWER- - Smaller effective focal spot -Better spatial resolution -More anode heel effect -Smaller max size of collimation What is the grid ratio? - CORRECT ANSWER- The height of the lead strips divided by the distance between lead strips Ratio = h/D Explain bit conversions for grids - CORRECT ANSWER- 5:1 Grid: 1 bit 8:1 / air gap: 2 bits 12:1 grid: 2.5 bits SID bit conversions - CORRECT ANSWER- 100cm-122cm: 0.5 bit 100cm-180cm: 1.5 bit 122cm- 180cm: 1 bit *every 25cm change is a 0.5 bit change* Bit conversions for part thickness - CORRECT ANSWER- Every 5cm change = 1 bit What errors will cause grid cut off with a parallel grid? - CORRECT ANSWER- -SID too small -Angling against grid lines -Grid and CR not perpendicular What errors will cause grid cut off with a focussed grid - CORRECT ANSWER- - Incorrect SID (off focus) -Angling against grid lines - Off center - Grid and CR not perpendicular

Meer zien Lees minder
Instelling
CAMRT
Vak
CAMRT

Voorbeeld van de inhoud

CAMRT PRACTICE EXAM
CERTIFIED QUESTIONS AND Answers
Verified 100% Correct


The air kerma rate must not exceed ___ from scattered radiation of radioscopic
equipment - CORRECT ANSWER- 2 mGy/h

HVL of Aluminum for given tube voltages? (70kV-150kV) - CORRECT ANSWER- 70:
2.5mm
80: 2.9mm
90: 3.2mm
100: 3.6mm
110: 3.9mm
120: 4.3mm
130: 4.7mm
140: 5.0mm
150: 5.4mm

How frequently should IP's and cassettes be cleaned and inspected? - CORRECT
ANSWER- Cleaned: monthly
Visual inspection: Weekly

What are daily QC tests for CR/DR/Fluoro/CT equipment - CORRECT ANSWER- -
Warm up (all)
-Meter operation (all)
-Equipment condition (all)
-System movements (fluoro)
-Visual assessment of electronic display devices (all)

What are weekly QC tests for CR/DR/Fluoro/CT equipment - CORRECT ANSWER- -
Visual inspection of cleanliness of system (all)
-Laser film printer operation (all)
-CT # accuracy
-CT noise
-CT uniformity

,What are monthly QC tests for CR/DR/Fluoro/CT equipment - CORRECT ANSWER- -
Cassette, screen, IP plate cleaning (CR)
-Retake analysis (CR/DR)
-Electronic display device performance (all)
-Laser film printer operation (all)
-CT slice thickness
-CT # calibration
-CT # linearity

What should the monthly retake analysis be below? - CORRECT ANSWER- 5% What
are quarterly QC tests for CR/DR/Fluoro/CT - CORRECT ANSWER- -Collimator
operation (CR/DR/Fluoro)
-Interlocks (all) (on doors to prevent exposure if door is open)
-Compression devices (Fluoro)
-Table angling/motion (Fluoro)
-Fluoro protection devices (lead drapes = .25mm of pb)
-CT patient support movement
-CT spatial resolution
-CT low contrast detectability

What are the annual QC tests for CR/DR/Fluoro/CT - CORRECT ANSWER- -Accuracy
of loading factors (CR/DR/fluoro)
-Output reproducibility
-Output linearity
-Beam filtration
-AEC
-Beam/light field alignment
- Beam collimation
-Grid performance
-EI
-Dynamic Range
-Spatial resolution
-Integrity of protective equipment

Flexion/ Extension views of the C spine assess? - CORRECT ANSWER-
Anteroposterior mobility

CR angle for an AP coccyx is - CORRECT ANSWER- 10 degrees caudad

What does ERCP stand for, what 2 things is it done for? - CORRECT ANSWER-
Endoscopic Retrograde Cholangiopancreatography

, 1. Diagnose biliary and pancreatic pathological conditions
2. Investigate gallbladder, CBD, pancreatic ducts, and intervention

Test tool used to test focal spot - CORRECT ANSWER- Slit camera, pinhole camera,
star pattern

State the line focus principle - CORRECT ANSWER- By angling the anode target the
effective focal spot is made much smaller than the actual focal spot

What are the effects of a smaller anode angle? (more vertical) - CORRECT ANSWER- -
Smaller effective focal spot
-Better spatial resolution
-More anode heel effect
-Smaller max size of collimation
What is the grid ratio? - CORRECT ANSWER- The height of the lead strips divided by
the distance between lead strips

Ratio = h/D

Explain bit conversions for grids - CORRECT ANSWER- 5:1 Grid: 1 bit
8:1 / air gap: 2 bits
12:1 grid: 2.5 bits

SID bit conversions - CORRECT ANSWER- 100cm->122cm: 0.5 bit
100cm->180cm: 1.5 bit
122cm-> 180cm: 1 bit

*every 25cm change is a 0.5 bit change*

Bit conversions for part thickness - CORRECT ANSWER- Every 5cm change = 1 bit

What errors will cause grid cut off with a parallel grid? - CORRECT ANSWER- -SID too
small
-Angling against grid lines
-Grid and CR not perpendicular

What errors will cause grid cut off with a focussed grid - CORRECT ANSWER- -
Incorrect SID (off focus)
-Angling against grid lines
- Off center
- Grid and CR not perpendicular

Geschreven voor

Instelling
CAMRT
Vak
CAMRT

Documentinformatie

Geüpload op
21 mei 2025
Aantal pagina's
19
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$13.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TopGradeGuru Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
15
Lid sinds
1 jaar
Aantal volgers
0
Documenten
2395
Laatst verkocht
2 maanden geleden
GRADEHUB

We provide access to a wide range of professionally curated exams for students and educators. It offers high-quality, up-to-date assessment materials tailored to various subjects and academic levels. With instant downloads and affordable pricing, it\'s the go-to resource for exam preparation and academic success.

1.5

2 beoordelingen

5
0
4
0
3
0
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen