TASER Training does NOT set? - Answers use of force policies, general orders, or procedures.
TASER Training does not give? - Answers Legal Advice
CEW stands for? - Answers Conducted Electrical Weapon
The safety switch on all TASER CEWs will remain in the? - Answers down (SAFE) position
TASER CEWs must not be pointed at? - Answers any person or body part
NMI stands for? - Answers Neuro-Muscular Incapacitation
There are different levels of Neuro-Muscular Incapacitation (NMI) ranging from? - Answers limited area
effects to significant body lockup
The greater the probe spread the higher? - Answers likelihood of NMI
True/False? CEWs may not achieve total NMI? - Answers True
True/False Subject may maintain muscle control? - Answers True
True/False Be prepared with other force options? - Answers True
Drive stuns alone cause only? - Answers localized pain, not NMI
True/False TASER Training does NOT require a CEW exposure for user certification? - Answers True
Voluntary CEW exposure is each agency's? - Answers sole and exclusive decision
CEW probe exposures involve strong muscle contractions and physical exertion similar to? - Answers
strenuous athletic activities
Benefits - Answers - For deployment
- Confidence to go "hands-on"
without receiving shock
- Self-defense
- Court expertise
- Secondary exposures
Risks - Answers - Stress, anxiety, panic
- Exertion and effects
, - Strong muscle contractions and effects
- Discomfort or painful experience
- Significant injuries have occurred
Safety Switch Down? - Answers Safe
Safety Switch Up? - Answers Armed
The ambidextrous safety switches do not operate? - Answers independently of each other
Single trigger cycle is how long? - Answers 5 seconds
To stop the discharge at anytime switch the safety? - Answers Down
Holding the trigger continuously beyond the 5 second cycle will? - Answers continue electrical discharge
until released
Once cartridge is fired, you can re-energzed by? - Answers Pulling the trigger again
Each trigger pull, when not cycling, will? - Answers Initiate another 5 second cycle
Additional trigger pulls during the 5 second cycle will? - Answers Not extend the cycle unless trigger is
held
The display counts up or down? - Answers Up
OO stands for? - Answers Stealth, no laser, no flashlight, CID dims
LO stands for? - Answers Laser only
OF stands for? - Answers Only flashlight
LF stands for? - Answers Laser and flashlight
The default setting is? - Answers Laser and Flashlight
We use what battery? - Answers XPPM
The APPM battery stops after? - Answers 5 seconds
A full spark functionality test should be performed every? - Answers everyday before shift starts
A fulk spark functionality test is used to? - Answers check sparking, check battery, ensure no fault icons
Taser cartridges are available in how many feet? - Answers 15, 21, 25
TASER cartridges are deployed by a? - Answers CEW electrical discharge