Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

MASS OIL BURNER NFPA 31 & NORA || 200 QUESTIONS AND CORRECT ANSWERS 2025 EXAM

Beoordeling
-
Verkocht
-
Pagina's
23
Cijfer
A+
Geüpload op
28-05-2025
Geschreven in
2024/2025

MASS OIL BURNER NFPA 31 & NORA || 200 QUESTIONS AND CORRECT ANSWERS 2025 EXAMMASS OIL BURNER NFPA 31 & NORA || 200 QUESTIONS AND CORRECT ANSWERS 2025 EXAMMASS OIL BURNER NFPA 31 & NORA || 200 QUESTIONS AND CORRECT ANSWERS 2025 EXAMMASS OIL BURNER NFPA 31 & NORA || 200 QUESTIONS AND CORRECT ANSWERS 2025 EXAMMASS OIL BURNER NFPA 31 & NORA || 200 QUESTIONS AND CORRECT ANSWERS 2025 EXAM

Meer zien Lees minder
Instelling
MASS OIL BURNER
Vak
MASS OIL BURNER

Voorbeeld van de inhoud

MASS OIL BURNER \ NFPA 31 &
NORA || 200 QUESTIONS AND
CORRECT ANSWERS 2025 EXAM




Cast iron fittings can be used in heating fuel systems? - ANSWER- False


Tank vent shall terminate - ANSWER- Within 12 feet of the fill and visible from
the fill


Tanks exceeding 330 gallons must have - ANSWER- Top supply connection


Fuel return piping from an appliance shall - ANSWER- Enter the top of the tank


Oil appliances burning used oil shall only be installed - ANSWER- In commercial
or industrial occupancies


Technician must be present for filling of new oil tank - ANSWER- False

,A common tank vent pipe shall be - ANSWER- One pipe size larger than the
largest individual vent pipe connected to it


If oil supply piping is not visible for inspection you must - ANSWER- Pressure or
vacuum test the line


Installation instructions for the care and operation of the appliance must be posted -
ANSWER- True


Oil burning appliances shall have - ANSWER- Limit control for pressure in
steam, temperature in water boiler, and temperature in furnace


Above ground tank installed inside must be pitched - ANSWER- Torwards the
supply at a pitch of 1/4 inch per foot


Outdoor tanks must be located - ANSWER- Five feet from property line for 275g
or smaller, ten feet for more than 275 but not exceeding 660g. Must be on concrete
slab


A chimney connector shall maintain a pitch or rise of - ANSWER- 1/4 inch per
foot


Minimal gauge thickness for steel flue pipe connectors less than nine inches in
diameter - ANSWER- 26 gauge


Oil fired water heater must be equipped with water temp, pressure, and vacuum
relief device - ANSWER- True

, Tank vent piping shall be - ANSWER- Pitched forward tank, terminate two feet
minimum from building openings, corrosion resistant weatherproof cap


Direct vent systems shall terminate - ANSWER- 4 feet horizontally from a
building opening


Fuel can be transferred from tank to appliance by pressurizing the tank -
ANSWER- False


Fusible link safety shutoff valves shall be located - ANSWER- Within six inches
of the filter between the tank and filter


Before installation of new oil burner you are required to - ANSWER- Inspect the
combustion chamber


A crankcase oil burner can be installed in any location where a standard oil burner
was located - ANSWER- False


Can tanks be installed in garages - ANSWER- Yes, if protected from vehicle
impacts by barriers


Teflon tape can be used on oil lines - ANSWER- False


The trial for ignition period for oil burners less than 20 GPM is? - ANSWER- 15
seconds


Fusible switches shall operate at a temp of - ANSWER- 165F

Geschreven voor

Instelling
MASS OIL BURNER
Vak
MASS OIL BURNER

Documentinformatie

Geüpload op
28 mei 2025
Aantal pagina's
23
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$19.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Anahsmith Walden University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
21
Lid sinds
2 jaar
Aantal volgers
9
Documenten
1239
Laatst verkocht
3 maanden geleden

4.0

3 beoordelingen

5
1
4
1
3
1
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen