U3 ICC Tank Tightness Testing WY
Study online at https://quizlet.com/_ecpy54
1. _______________ cathodic protection systems can influence other nearby
metallic structures that are not part of the protected system.: Impressed-cur-
rent
2. ___________________ and fittings are used to separate buried piping from
above ground piping and tanks from piping.: Dielectric bushings
3. On a steel tank without cathodic protection, if a coating is flawed, what
happens at the flaw?
a. Cathodic surface is increased
b. Current flow is increased from this area
c. Current flow is increased to this area: b. Current flow is increased from this
area
4. On an impressed current cathodic protection system, the negative wire of
the rectifier is connected to the:
a. Anode
b. Cathode
c. Drop tube
d. Dielectric union: b. Cathode
5. All are examples of acceptable release detection for tanks, except:
a. Impressed current cathodic protection
b. Automatic tank gauging
c. Statistical inventory reconciliation
d. Soil-vapor monitoring: a. Impressed current cathodic protection
6. When a tank is temporarily closed, the cathodic protection system:
a. Must be turned off
b. Must remain in operation
c. Should be removed
d. Operator can have it on or off.: b. Must remain in operation
7. When a steel tank is installed with a galvanic CP system attached, the tank
gauges are usually connected through a riser with a dielectric bushing. What
is the purpose of that?
a. To prevent static discharge
b. To minimize effects of noise
c. To electrically isolate the tank from the tank gauge
d. To prevent water intrusion in the tank: c. To electrically isolate the tank from
the tank gauge
8. Factory-installed diectric coatings may include all of the following except:
a . Asphalt
b. epoxies



, U3 ICC Tank Tightness Testing WY
Study online at https://quizlet.com/_ecpy54
c. Enamels
d. fiberglass-reinforced plastic: a . Asphalt
9. According to the EPA, Tank tightness test data must be maintained for:
a. 18 months
b. 3 years
c. 5 years
d. Until the next test is performed: d. Until the next test is performed
10. How long must records of UST system repairs be available on site?
a. 60 days
b. 1 year
c. 5 years
d. for the remaining lifetime of the UST system: d. for the remaining lifetime of
the UST system
11. In the event of a release, what is the reporting requirement?
a. ICC licensed supervisor must report the leak within 24 hours
b. Owner/Operator must report the leak within 24 hours
c. Owner/Operator must report the leak within 18 hours
d. ICC licensed supervisor must report the leak within 18 hours: b. Owner/Op-
erator must report the leak within 24 hours
12. At what size spill does it need to be reported?
a. 5 gallons
b. 10 gallons
c. 15 gallons
d. 25 gallons: d. 25 gallons
13. Contamination of soils is encountered before removing a tank. The clean
up must be initiated by the:
a. Fire Marshal
b. Ecology inspector
c. Owner / operator of the UST system
d. Landlord: c. Owner / operator of the UST system
14. All are examples of overfill protection, except:
a. Vent restricting device
b. Drop tube with an automatic shut off device
c. Audible and visual alarm
d. Expandable bladder in manway: d. Expandable bladder in manway
15. Definition: An observation well is located:
a. Outside the tank excavation, but within 25 feet
b. Inside the tank excavation, extending 1' below the bottom of the tanks
c. Inside the tank excavation, no deeper than 15 feet


, U3 ICC Tank Tightness Testing WY
Study online at https://quizlet.com/_ecpy54
d. Outside the tank excavation until ground water is reached: b. Inside the tank
excavation, extending 1' below the bottom of the tanks
16. A monitoring well lid is marked with a:
a. Black lid with a white equilateral triangle
b. White lid with a black equilateral triangle: b. White lid with a black equilateral
triangle
17. What is the main purpose of clearly marking and securing monitoring well
caps?
a. To prevent people from removing water
b. ensure only geologist access the water
c. Prevent delivery drivers from mistakenly dumping fuel in the well
d. Prevent ice build-up: c. Prevent delivery drivers from mistakenly dumping fuel
in the well
18. All of the following are considered part of the secondary containment
system EXCEPT:
a. Under dispenser containment
b. Monitoring well
c. Containment sensor
d. Double wall piping: b. Monitoring well
19. Recommended interstitial monitoring includes the following:
a. Soil vapor monitoring
b. Impervious liner with a well to measure any release
c. Groundwater monitoring
d. Sensors installed in containment sumps: d. Sensors installed in containment
sumps
20. A vapor collection tank (vapor pot) is located between the underground
tanks and dispensers. It is designed to:
a. collect and condense vapors so they can be measured and reported to the
local air authority.
b. allow collection of condensed vapors at a low point and a means to remove
them.
c. remove condensed vapors from the UST system to be disposed of when the
tank reaches no more than 95% full.: b. allow collection of condensed vapors at
a low point and a means to remove them.
21. When cool fuel is added to a tank with warmer fuel, the following is true:
a. The fuel temperature will raise and the product will expand.
b. The fuel temperature will lower and the product will contract
c. The fuel temperature will lower and the product will expand.: b. The fuel
temperature will lower and the product will contract

Geschreven voor

Instelling
U3 ICC TANK TIGHTNESS TESTING
Vak
U3 ICC TANK TIGHTNESS TESTING

Documentinformatie

Geüpload op
29 mei 2025
Aantal pagina's
23
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
SmarttDocs Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
124
Lid sinds
1 jaar
Aantal volgers
5
Documenten
1241
Laatst verkocht
3 weken geleden
SMARTDOCS

Welcome to Smartdocs– your go-to source for high-quality study guides, question banks, and exam-focused materials for every subject and level. Whether you're cramming for a last-minute test or aiming for top marks, our clear, accurate, and easy-to-use documents are designed to help you succeed faster. Trusted by students, built for results – level up your learning today!

4.9

39 beoordelingen

5
36
4
2
3
1
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen