QUESTIONS AND CORRECT ANSWERS
Your hard hat is intended to protect you from which of the following? - CORRECT
ANSWER Impact, penetration, and electric shock
Which standard is imprinted on glasses or goggles that meet safety
requirements? - CORRECT ANSWER ANSI Standard Z87.1-2010
Which items of PPE do you need under normal working conditions (not
climbing)? - CORRECT ANSWER Hard hat, safety glasses, safety vest, FVD, and
gloves
Which items of PPE would you need when working aloft on a ladder? - CORRECT
ANSWER Hard hat, safety glasses, FVD, long-sleeved shirt, gloves, body belt,
positioning strap, and lineman's boots
What happens to leather when it is dried too fast in excessive heat? - CORRECT
ANSWER The leather curls and cracks
How do you measure for proper "D" size on a padded body belt? - CORRECT
ANSWER Measure hipbone to hipbone plus 2"
Once at the working height, pass the positioning strap around the pole
and engage the single-sided end on the D-Ring with the mouth of the
snap hook _____________. - CORRECT ANSWER Outward
Always verify visually that the snap hook has engaged the
__________________. - CORRECT ANSWER D-Ring
, You must document your monthly PPE inspection on the applicable
inspection form. - CORRECT ANSWER True
What type of safety vest is required? - CORRECT ANSWER Class 3
What is the minimum clearance of CATV cable from power at the pole? - CORRECT
ANSWER 40 inches
What are the three indicators on the FVD? - CORRECT ANSWER 10-step bar graph,
audible tone, and power indicator LED
To use the FVD, after the self-test process, continue to hold pressure on
the power switch and move the FVD: - CORRECT ANSWER Toward the object you
want to test
To replace the battery of the FVD, use this tool to pry the cover off the
back of the device: - CORRECT ANSWER Putty knife, coin or, small screwdriver
The FVD is only a voltage detector and is not intended to be a precision
measuring device. What other senses would you use as an additional
safety check? - CORRECT ANSWER Sight, sound, and smell
To determine if capacitive coupling is causing a hazardous voltage
indication, you should provide a temporary path to __________ for your
body to remove the voltage caused by the e-field of the power line. - CORRECT
ANSWER Ground
Indications of high current include - CORRECT ANSWER Charring or melting of
wires, and smoke